EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitFallbericht

Rapidly growing mycobacteria in cardiac implantable electronic device infections: a case series and literature review

Jose Delgado Moreno, Miguel Herrera, Roger Carrillo

Infection · 2026

DOI: 10.1007/s15010-026-02808-9 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Infection, 2026. Verfasst von Jose Delgado Moreno und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Critical Care, Mayo Clinic, San Pablo Road, Jacksonville, 32224, Florida, USA. delgado.jose@mayo.edu. Hauptthemen laut MEDLINE: Prosthesis-Related Infections, Defibrillators, Implantable, Pacemaker, Artificial, Mycobacterium Infections, Nontuberculous. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Rapidly growing mycobacteria (RGM) are uncommon causes of cardiac implantable electronic device (CIED) infection and present unique diagnostic and therapeutic challenges. Data describing their clinical characteristics, management, and outcomes remain limited, and comparative information with tuberculous mycobacterial CIED infections is scarce. This study aimed to describe a single-center case series of RGM-associated CIED infections and to synthesize published cases to characterize clinical presentation, management, and outcomes, with exploratory comparison to Mycobacterium tuberculosis CIED infections.

Methods

We reviewed a prospectively maintained lead extraction registry at a single center (January 2003–August 2024) to identify cases of RGM CIED infection. We also performed a structured literature review of published mycobacterial CIED infections using predefined search terms and eligibility criteria, followed by descriptive analyses and exploratory comparisons between RGM and M. tuberculosis cases.

Results

Among 1120 patients undergoing lead extraction for CIED infection, 3 cases (0.3%) were caused by RGM ( Mycobacterium fortuitum , n = 2; Mycobacterium abscessus complex , n = 1). All 3 institutional cases occurred weeks to months after device implantation and presented as pocket or lead-associated infections. Initial blood cultures were negative in 1 case. Complete device removal was achieved in all 3 cases; 2 patients survived following targeted antimicrobial therapy, whereas 1 died from postoperative multiorgan failure. No relapses were observed during available follow-up in the surviving patients (1 and 3 years). The literature review identified 46 additional mycobacterial CIED infections (38 RGM, 8 M. tuberculosis ). Patients with RGM infections presented significantly earlier than those with M. tuberculosis infections (median 60 [21–365] vs. 450 [330–1825] days, p = 0.011), and RGM cases were more likely to undergo complete extraction (90% vs. 50%, p = 0.017). Other differences were difficult to interpret because of the small number of cases.

Conclusions

RGM are rare causes of CIED infection that may present after recent device manipulation or with initially negative cultures. In this exploratory analysis, RGM infections were more often pocket-centered and more frequently managed with complete device extraction than M. tuberculosis infections. Early recognition, microbiologic diagnosis, complete device removal, and targeted multidrug antimicrobial therapy were associated with favorable outcomes in most cases. Graphical abstract Recognition, clinical presentation, and outcomes of cardiac implantable electronic device (CIED) infections due to rapidly growing mycobacteria (RGM) compared with Mycobacterium tuberculosis . Early onset after device manipulation (RGM) versus delayed onset (TB), indolent pocket findings, prior device reintervention, and negative routine cultures should raise suspicion for mycobacterial infection. RGM infections present earlier and are more frequently managed with complete device extraction compared with TB, with favorable outcomes when treated with complete device and lead removal followed by prolonged targeted antimicrobial therapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis-Related InfectionsDefibrillators, ImplantablePacemaker, ArtificialMycobacterium Infections, NontuberculousHumansAgedFemaleMaleMiddle AgedMycobacterium fortuitumDevice Lead ExtractionAged, 80 and overMycobacterium abscessusDevice Removal

Stichwörter der Autor:innen

Mycobacterium tuberculosisCIED infectionEndocarditisLead extractionRapidly growing mycobacteria

Autor:innen und Institutionen

  • Department of Critical Care, Mayo Clinic, San Pablo Road, Jacksonville, 32224, Florida, USA. delgado.jose@mayo.edu.
  • Department of Clinical Investigation and Tropical Medicine, Gorgas Memorial Institute for Health Studies, Panama, Panama.
  • The Heart Institute at Palmetto General Hospital, Hialeah, Florida, USA.

Zitieren

APA

Delgado Moreno, J., Herrera, M., & Carrillo, R. (2026). Rapidly growing mycobacteria in cardiac implantable electronic device infections: a case series and literature review. Infection. https://doi.org/10.1007/s15010-026-02808-9

Vancouver

Delgado Moreno J, Herrera M, Carrillo R. Rapidly growing mycobacteria in cardiac implantable electronic device infections: a case series and literature review. Infection. 2026. doi:10.1007/s15010-026-02808-9

BibTeX
@article{DelgadoMoreno2026,
  author = {Delgado Moreno, Jose and Herrera, Miguel and Carrillo, Roger},
  title = {Rapidly growing mycobacteria in cardiac implantable electronic device infections: a case series and literature review},
  journal = {Infection},
  year = {2026},
  doi = {10.1007/s15010-026-02808-9}
}
Kostenlos starten →