EUVIMEDObjevte EUVIMED
ÜbersichtsarbeitOpen access · CC BY-NC-ND 4.0

Role of Routine Electrophysiological Study Performed During Transcatheter Aortic Valve Replacement to Predict AV Block

Mattia Pagnoni iD, David Meier, Adrian Luca iD, Stephane Fournier, Farhang Aminfar, Christelle Haddad, Niccolo Maurizi, Giulia Domenichini, Mathieu Le Bloa, Claudia Herrera Siklody, Cheryl Teres, Stephane Cook and 10 more

Pacing and Clinical Electrophysiology · 2025

DOI: 10.1111/pace.15159 ↗

At a glance

Übersichtsarbeit in Pacing and Clinical Electrophysiology, 2025. Written by Mattia Pagnoni and 21 co-authors. Institution: Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland. Major MEDLINE topics: Transcatheter Aortic Valve Replacement, Atrioventricular Block, Electrocardiography, Electrophysiologic Techniques, Cardiac. Cited 3 times so far (Crossref); 21 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Fondation vaudoise de cardiologie interventionnelle.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Periprocedural electrophysiological (EP) testing may be useful to predict high degree atrioventricular block (HAVB) risk in patients undergoing transcatheter aortic valve replacement (TAVR).

Objective

To determine whether pre‐ and immediate post‐TAVR ECG and HV interval findings are predictive of HAVB.

Methods

Consecutive TAVR patients without prior pacemaker (PM) implantation underwent ECG and standardized HV interval measurements pre‐ and post‐TAVR using the quadripolar catheter for rapid pacing. The primary outcome was HAVB >24 h after TAVR or ventricular pacing need Results Out of 97 included patients, 8 experienced the primary outcome (7 with HAVB and 1 with PM need). On univariate analysis, pre‐ and post‐TAVR PR, post‐TAVR HV, and Delta‐HV intervals were predictors of the primary outcome. A Delta‐HV interval ≥18 ms predicted HAVB with sensitivity = 50% and specificity = 90% (AUC = 0.708, PPV = 31%), while an HV interval ≥60 ms after TAVR had sensitivity = 63% and specificity = 79% (AUC = 0.681, PPV = 21%). None of the patients with a PR interval ≤180 ms post‐TAVR experienced the primary outcome. Among patients with new‐onset LBBB, an HV interval post‐TAVR >65 ms was the only predictor of HAVB (AUC = 0.776, PPV = 33%, and NPV = 97%).

Conclusion

The yield of periprocedural EP assessment during TAVR is limited considering that about half of the at‐risk patients fail to be identified. However, early periprocedural risk stratification may be more useful in the subset of patients with new‐onset LBBB. Among ECG findings, a post‐TAVR PR interval ≤180 ms identifies a subgroup at very low risk, independently of QRS interval and morphology.

Subjects

MeSH terms (MEDLINE)

Transcatheter Aortic Valve ReplacementAtrioventricular BlockElectrocardiographyElectrophysiologic Techniques, CardiacAortic Valve StenosisHumansFemaleMaleAged, 80 and overAgedPredictive Value of Tests

Author keywords

HV intervalatrioventricular blockelectrophysiological studypermanent pacemaker implantationtrans‐catheter aortic valve replacement

Authors and institutions

  • Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland.
  • Arrhythmias Unit, Louis Pradel Cardiovascular Hospital, Hospices Civils de Lyon, Lyon, France.
  • Department of Cardiology, Clinique Cecil, Hirslanden Group, Lausanne, Switzerland.
  • Department of Cardiology, University & Hospital Fribourg, Fribourg, Switzerland.

ORCID profiles: Mattia Pagnoni, Adrian Luca

Funding

  • Fondation vaudoise de cardiologie interventionnelle

Cite

APA

Pagnoni, M., Meier, D., Luca, A., Fournier, S., Aminfar, F., Haddad, C., Maurizi, N., Domenichini, G., Le Bloa, M., Herrera Siklody, C., Teres, C., Cook, S., Goy, J. J., Togni, M., Roguelov, C., Girod, G., Rubimbura, V., Dupré, M., Eeckhout, E., …, & Pascale, P. (2025). Role of Routine Electrophysiological Study Performed During Transcatheter Aortic Valve Replacement to Predict AV Block. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.15159

Vancouver

Pagnoni M, Meier D, Luca A, Fournier S, Aminfar F, Haddad C, et al. Role of Routine Electrophysiological Study Performed During Transcatheter Aortic Valve Replacement to Predict AV Block. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.15159

BibTeX
@article{Pagnoni2025,
  author = {Pagnoni, Mattia and Meier, David and Luca, Adrian and Fournier, Stephane and Aminfar, Farhang and Haddad, Christelle and Maurizi, Niccolo and Domenichini, Giulia and Le Bloa, Mathieu and Herrera Siklody, Claudia and Teres, Cheryl and Cook, Stephane and Goy, Jean-Jacques and Togni, Mario and Roguelov, Christan and Girod, Grégoire and Rubimbura, Vladimir and Dupré, Marion and Eeckhout, Eric and Pruvot, Etienne and Muller, Olivier and Pascale, Patrizio},
  title = {Role of Routine Electrophysiological Study Performed During Transcatheter Aortic Valve Replacement to Predict AV Block},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  doi = {10.1111/pace.15159}
}
Start for free →