Impact of early PR interval prolongation after transcatheter aortic valve Implantation (TAVI) on the onset of high-grade conduction disturbances
Clinical Research in Cardiology · 2026
DOI: 10.1007/s00392-025-02811-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Research in Cardiology, 2026. Verfasst von Grégoire Massoullie und 9 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department, CHU Clermont-Ferrand, Rue Montalembert, 63000, Clermont-Ferrand, France. gmassoullie@chu-clermontferrand.fr. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Electrocardiography, Atrioventricular Block, Aortic Valve Stenosis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND AND AIMS: High-grade atrioventricular conduction disorders or blocks (HAVB) are common complications following Transcatheter Aortic Valve Implantation (TAVI). This study aimed to evaluate the incidence and prognostic significance of PR interval prolongation at Day 1 (D1) after TAVI on the risk of HAVB and pacemaker implantation (PPI). METHODS: This is a single-center retrospective cohort including 1151 patients who underwent TAVI from January 2010 to December 2020. PR interval prolongation was measured between pre-TAVI and D1 ECG. The primary endpoint was HAVB leading to PPI at 10 days. Based on multivariable model, Day-1 ECG risk score was developed using PR, QRS duration and valve type. RESULTS: The mean PR interval prolongation at D1 was 8 ± 28 ms, 20.8% developed a type 1 AV block. A PR-interval prolongation ≥ 40 ms at Day 1 was an independent predictor of HAVB requiring PPI in patients with QRS ≥ 100 ms (HR = 2.8 [1.8-4.1], p < 0.001), with a 10-day incidence of 39.2%, compared with 7.0% in those with QRS < 100 ms (p < 0.001). The Day-1 ECG risk score classified patients according to increasing 10-day HAVB rates of 5.4%, 17.7%, and 32.7% in the low-, intermediate-, and high-risk groups, respectively (p < 0.001). CONCLUSIONS: PR interval prolongation ≥ 40 ms at D1 after Transcatheter Aortic Valve Implantation is a strong predictor of high-grade atrioventricular conduction disorders or blocks requiring pacemaker implantation, particularly in patients with QRS ≥ 100 ms. A Day-1 ECG risk score provides a simple bedside tool to optimize discharge strategies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology Department, CHU Clermont-Ferrand, Rue Montalembert, 63000, Clermont-Ferrand, France. gmassoullie@chu-clermontferrand.fr.
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, Institut Pascal, 63000, Clermont-Ferrand, France. gmassoullie@chu-clermontferrand.fr.
- Cardiology Department, CHU Clermont-Ferrand, Rue Montalembert, 63000, Clermont-Ferrand, France.
- Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, Institut Pascal, 63000, Clermont-Ferrand, France.
- Biostatistics Unit (Clinical Research and Innovation Direction), CHU Clermont-Ferrand, Clermont-Ferrand, France.
Zitieren
APA
Massoullie, G., Bouchant-Pioche, M., Pereira, B., Boudias, A., Souteyrand, G., Catalan, P. A., Abu-Alrub, S., Combaret, N., Clerfond, G., & Eschalier, R. (2026). Impact of early PR interval prolongation after transcatheter aortic valve Implantation (TAVI) on the onset of high-grade conduction disturbances. Clinical Research in Cardiology. https://doi.org/10.1007/s00392-025-02811-4
Vancouver
Massoullie G, Bouchant-Pioche M, Pereira B, Boudias A, Souteyrand G, Catalan PA, et al. Impact of early PR interval prolongation after transcatheter aortic valve Implantation (TAVI) on the onset of high-grade conduction disturbances. Clinical Research in Cardiology. 2026. doi:10.1007/s00392-025-02811-4
BibTeX
@article{Massoullie2026,
author = {Massoullie, Grégoire and Bouchant-Pioche, Marion and Pereira, Bruno and Boudias, Antoine and Souteyrand, Géraud and Catalan, Pierre-Antoine and Abu-Alrub, Saer and Combaret, Nicolas and Clerfond, Guillaume and Eschalier, Romain},
title = {Impact of early PR interval prolongation after transcatheter aortic valve Implantation (TAVI) on the onset of high-grade conduction disturbances},
journal = {Clinical Research in Cardiology},
year = {2026},
doi = {10.1007/s00392-025-02811-4}
}
EUVIMED