Randomized Controlled Trial Comparing Training of Transseptal Puncture With or Without Intracardiac Echocardiography
Pacing and Clinical Electrophysiology · 2024
DOI: 10.1111/pace.15081 ↗At a glance
Randomisierte kontrollierte Studie in Pacing and Clinical Electrophysiology, 2024. Written by Qi Guo and 11 co-authors. Institution: Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing…. Major MEDLINE topics: Punctures, Echocardiography, Atrial Fibrillation, Catheter Ablation. 14 references. Funded by: Biosense Webster, Inc., Beijing Hospitals Authority Innovation Studio of Young Staff Funding Support, code: 202316.
Abstract (original language)
Background
Intracardiac echocardiography (ICE) has been widely used in the catheter ablation of atrial fibrillation (AF). However, the value of ICE in the training of transseptal puncture (TSP) is unclear.
Methods
ICE‐Training Study was a single‐center, parallel‐group, unmasked, randomized controlled trial registered in ChineseClinicalTrials.gov. Participants were randomly assigned (1:1) to different groups (1) the ICE simulator training group (ICE‐ST), in which TSP was trained and performed under the guidance of both ICE and x‐ray; and (2) the conventional simulator training group (Con‐ST), in which TSP was trained and performed only under the guidance of x‐ray. The trainees need to undergo the training stage and the evaluation stage.
Results
From October 2022 to December 2022, 18 consecutive fellows (age 32.4 ± 4.4 years, 12 males) without experience of TSP were included. The training period (16.9 ± 6.6 vs. 29.6 ± 8.7 times, p = 0.003) and the fluoroscopy time (120.3 ± 25.3 vs. 189.3 ± 40.2 s, p < 0.001) of the ICE‐ST group was significantly shorter than that of the Con‐ST group. No significant difference was found in the comprehensive performance of TSP in the ICE‐ST group (composite score 96.7 ± 5.7) and the Con‐ST group (composite score 95.9 ± 6.3, p = 0.62), but the selection of TSP sites in the ICE‐ST group was commonly better than that in the Con‐ST group.
Conclusions
ICE could improve the efficiency of TSP training and optimize the site of TSP to facilitate catheter manipulation in the ablation. Trial Registration ChineseClinicalTrials.gov identifier: ChiCTR2200058377
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, National Clinical Research Center for Cardiovascular Diseases, Beijing, China.
ORCID profiles: Qi Guo, Caihua Sang, Yiwei Lai, Mingyang Gao, Song Zuo, Deyong Long, Jianzeng Dong, Changsheng Ma
Funding
- Biosense Webster, Inc.
- Beijing Hospitals Authority Innovation Studio of Young Staff Funding Support, code: 202316
Cite
APA
Guo, Q., Sang, C., Lai, Y., Gao, M., Guo, X., Dai, W., Li, S., Liu, N., Zuo, S., Long, D., Dong, J., & Ma, C. (2024). Randomized Controlled Trial Comparing Training of Transseptal Puncture With or Without Intracardiac Echocardiography. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.15081
Vancouver
Guo Q, Sang C, Lai Y, Gao M, Guo X, Dai W, et al. Randomized Controlled Trial Comparing Training of Transseptal Puncture With or Without Intracardiac Echocardiography. Pacing and Clinical Electrophysiology. 2024. doi:10.1111/pace.15081
BibTeX
@article{Guo2024,
author = {Guo, Qi and Sang, Caihua and Lai, Yiwei and Gao, Mingyang and Guo, Xueyuan and Dai, Wenli and Li, Songnan and Liu, Nian and Zuo, Song and Long, Deyong and Dong, Jianzeng and Ma, Changsheng},
title = {Randomized Controlled Trial Comparing Training of Transseptal Puncture With or Without Intracardiac Echocardiography},
journal = {Pacing and Clinical Electrophysiology},
year = {2024},
doi = {10.1111/pace.15081}
}
EUVIMED