Journal article in Pacing and Clinical Electrophysiology, 2024. Written by Sutopa Purkayastha and 3 co-authors. Institution: Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York, USA. Major MEDLINE topics: Cardiac Resynchronization Therapy Devices. 20 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Cardiac resynchronization therapy (CRT) improves ventricular function, but a positive response to CRT is often limited due to left ventricular (LV) lead placement in a suboptimal position. Complex coronary venous anatomy can hinder the placement of an LV lead in the target vessel, leading to poor CRT response.

Objective

To report experience with snare‐assisted LV lead delivery in CRT and compare outcomes with the conventional LV lead delivery.

Methods

This is a single‐center retrospective case–control study of CRT implants between 2016 and 2021. Snare‐assisted lead delivery was performed in cases where conventional lead placement failed or when a preferred target vessel had anatomy amenable to the technique. Safety and outcomes were compared to conventional LV lead placement cases.

Results

Among 180 CRT cases, 33 were snare‐assisted, and 147 were conventional LV lead placements. Median follow‐up was 924 days in the snare and 618.5 days in the control group. The lead placement was successful in 28/33 snare and 138/147 control cases. A mid‐vessel segment was attained in 89.3% of snare and 72.5% of control cases( p = .03). The apical position was more frequently observed in the control group (26.8% vs. 7.1%, p = .03). All‐cause mortality trended lower in the snare group (6.1%) compared to (17.1%) in the control group ( p = .13).

Conclusion

Snare‐assisted LV lead delivery is a safe and effective technique that can be utilized for overcoming complex venous anatomy.

Subjects

MeSH terms (MEDLINE)

Cardiac Resynchronization Therapy DevicesHumansRetrospective StudiesMaleFemaleAgedCase-Control StudiesCardiac Resynchronization TherapyHeart VentriclesProsthesis ImplantationMiddle AgedElectrodes, ImplantedHeart Failure

Author keywords

antidromic snarebiventricular pacingcardiac resynchronization therapyleft ventricular leadorthodromic snare

Authors and institutions

  • Montefiore-Einstein Center for Heart and Vascular Care, Albert Einstein College of Medicine, Bronx, New York, USA.

Cite

APA

Purkayastha, S., Reynbakh, O., Krishnan, S., & Guttenplan, N. (2024). Safety and efficacy of orthodromic snare technique in left ventricular lead delivery in cardiac resynchronization implantation. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.15066

Vancouver

Purkayastha S, Reynbakh O, Krishnan S, Guttenplan N. Safety and efficacy of orthodromic snare technique in left ventricular lead delivery in cardiac resynchronization implantation. Pacing and Clinical Electrophysiology. 2024. doi:10.1111/pace.15066

BibTeX
@article{Purkayastha2024,
  author = {Purkayastha, Sutopa and Reynbakh, Olga and Krishnan, Suraj and Guttenplan, Nils},
  title = {Safety and efficacy of orthodromic snare technique in left ventricular lead delivery in cardiac resynchronization implantation},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2024},
  doi = {10.1111/pace.15066}
}