EUVIMEDEUVIMED entdecken
Fallbericht

Left ventricular CRT‐D lead implantation using the retrograde approach following lateral vein balloon angioplasty

Erwin Ciechański iD, Piotr Denysiuk iD, Krystian Ciechański iD, Tomasz Chromiński, Marcin Szczasny, Piotr Błaszczak, Andrzej Głowniak iD

Pacing and Clinical Electrophysiology · 2024

DOI: 10.1111/pace.14803 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Pacing and Clinical Electrophysiology, 2024. Verfasst von Erwin Ciechański und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Stefan Cardinal Wyszynski Regional Specialist Hospital, Lublin, Poland. Hauptthemen laut MEDLINE: Prosthesis Implantation. Die Arbeit nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A 60‐year‐old female with heart failure with reduced left ventricle ejection fraction, implantable cardiac defibrillator and left bundle branch block was admitted to Department of Cardiology for cardiac resynchronization therapy defibrillator upgrade. Due to difficulties with advancement of left ventricular lead to lateral coronary vein, balloon angioplasty with use of retrograde approach via collateral branches and two CS sheaths positioning was performed. Final position of lead in lateral vein was achieved resulting with pacing threshold of 0.7 V/0.5 ms, impedance of 720 Ω and QRS of 130 ms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis ImplantationHumansFemaleMiddle AgedCardiac Resynchronization Therapy DevicesDefibrillators, ImplantableHeart FailureAngioplasty, BalloonElectrodes, ImplantedBundle-Branch BlockCardiac Resynchronization Therapy

Stichwörter der Autor:innen

cardiac resynchronization therapycoronary sinuscoronary vein angioplastyheart failureretrograde

Autor:innen und Institutionen

  • Department of Cardiology, Stefan Cardinal Wyszynski Regional Specialist Hospital, Lublin, Poland.
  • Department of Toxicology, Medical University of Lublin, Lublin, Poland.
  • Department of Gastroenterology, Stefan Cardinal Wyszynski Regional Specialist Hospital, Lublin, Poland.
  • Department and Clinic of Cardiology, Medical University of Lublin, Lublin, Poland.

ORCID-Profile: Erwin Ciechański, Piotr Denysiuk, Krystian Ciechański, Andrzej Głowniak

Zitieren

APA

Ciechański, E., Denysiuk, P., Ciechański, K., Chromiński, T., Szczasny, M., Błaszczak, P., & Głowniak, A. (2024). Left ventricular CRT‐D lead implantation using the retrograde approach following lateral vein balloon angioplasty. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14803

Vancouver

Ciechański E, Denysiuk P, Ciechański K, Chromiński T, Szczasny M, Błaszczak P, et al. Left ventricular CRT‐D lead implantation using the retrograde approach following lateral vein balloon angioplasty. Pacing and Clinical Electrophysiology. 2024. doi:10.1111/pace.14803

BibTeX
@article{Ciechaski2024,
  author = {Ciechański, Erwin and Denysiuk, Piotr and Ciechański, Krystian and Chromiński, Tomasz and Szczasny, Marcin and Błaszczak, Piotr and Głowniak, Andrzej},
  title = {Left ventricular CRT‐D lead implantation using the retrograde approach following lateral vein balloon angioplasty},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2024},
  doi = {10.1111/pace.14803}
}
Kostenlos starten →