Optimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting
JACC: Clinical Electrophysiology · 2025
DOI: 10.1016/j.jacep.2025.01.022 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift JACC: Clinical Electrophysiology, 2025. Verfasst von Willem Gerrits und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands. Electronic address: W.Gerrits-4@umcutrecht.nl. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Heart Failure, Cardiac Resynchronization Therapy Devices, Magnetic Resonance Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: ZonMw.
Abstract (Originalsprache)
BACKGROUND: To improve cardiac resynchronization therapy (CRT) an on-screen image-guidance platform, CARTBox-Suite (CART-Tech B.V.), was developed to identify left ventricular pacing electrode (LVPE) implantation sites and facilitate precise LVPE placement. This multicenter randomized trial evaluated the efficacy of image guidance on LVPE implantation accuracy and its impact on left ventricular end-systolic volume (LVESV) reduction 6 months after CRT. OBJECTIVES: The aim of this trial is to improve the accuracy and efficacy of LVPE placement in CRT. METHODS: A total of 131 heart failure patients (80% with Class I CRT indication) were enrolled across 7 hospitals in the Netherlands. CARTBox-Suite, which utilizes a cloud-based AI algorithm, was used to identify a target area with late mechanical activation based on cardiac magnetic resonance imaging. Scarred areas marked by late gadolinium enhancement were excluded. Patients were randomized to image-guided implantation, with on-screen guidance during the procedure or conventional implantation. RESULTS: The primary endpoint, LVPE implantation in the target area, was achieved significantly more often in the image-guided group (66.7% vs 29.2%; P < 0.001). The secondary endpoint was fewer LVPE placed in scarred areas in the image-guided group (7.1% vs 36.4%; P = 0.006). Mean LVESV reduction was greater in the image-guided group (43.2% vs. 37.6%), although not significantly (P = 0.166). Patients with myocardial scar showed greater LVESV reduction with image guidance (40.7% vs 27.7%; P = 0.028). CONCLUSIONS: Image-guided implantation resulted in significantly more LVPE placed in the target area and greater LVESV reduction in patients with myocardial scar.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands. Electronic address: W.Gerrits-4@umcutrecht.nl.
- Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands.
- Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands; Department of Cardiology, Haga Teaching Hospital, the Hague, the Netherlands.
- Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center, Maastricht, the Netherlands.
- Department of Cardiology, Amsterdam University Medical Center, Amsterdam, the Netherlands.
- Department of Cardiology, St. Antonius Hospital, Nieuwegein, the Netherlands.
Förderung
- ZonMw
Zitieren
APA
Gerrits, W., Wouters, P. C., Chiu, C. S. L., Guglielmo, M., Cramer, M. J., van der Harst, P., Vernooy, K., van Stipdonk, A. M. W., van Halm, V. P., van Dijk, V. F., Ghani, A., Maass, A. H., Yap, S. C., van Slochteren, F. J., & Meine, M. (2025). Optimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting. JACC: Clinical Electrophysiology. https://doi.org/10.1016/j.jacep.2025.01.022
Vancouver
Gerrits W, Wouters PC, Chiu CSL, Guglielmo M, Cramer MJ, van der Harst P, et al. Optimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting. JACC: Clinical Electrophysiology. 2025. doi:10.1016/j.jacep.2025.01.022
BibTeX
@article{Gerrits2025,
author = {Gerrits, Willem and Wouters, Philippe C and Chiu, Cheyenne S L and Guglielmo, Marco and Cramer, Maarten J and van der Harst, Pim and Vernooy, Kevin and van Stipdonk, Antonius M W and van Halm, Vokko P and van Dijk, Vincent F and Ghani, Abdul and Maass, Alexander H and Yap, Sing-Cien and van Slochteren, Frebus J and Meine, Mathias},
title = {Optimizing CRT Lead Placement Accuracy With CMR-Guided On-Screen Targeting},
journal = {JACC: Clinical Electrophysiology},
year = {2025},
doi = {10.1016/j.jacep.2025.01.022}
}
EUVIMED