EUVIMEDОткрийте EUVIMED
Crossref

PECS II block for cardiac implantable electronic device insertion: A pilot study

Mustafa Kilin iD, Ali Sait Kavakli iD, Arzu Karaveli iD, Tayfun Sugur iD, Gorkem Kus iD, Goksel Cagirci iD, Sakir Arslan iD

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14811 ↗

At a glance

Journal article in Pacing and Clinical Electrophysiology, 2023. Written by Mustafa Kilin and 6 co-authors. Institution: Department of Anesthesiology and Reanimation, University of Health Sciences Antalya Training and Research Hospital, Antalya, Turkey. Major MEDLINE topics: Defibrillators, Implantable, Pacemaker, Artificial, Nerve Block, Prosthesis Implantation. Cited 9 times so far (Crossref); 32 references.

РезюмеSubjectsБиблиографски данниCiteRelated studies

Abstract (original language)

Aim

Some truncal blocks could provide adequate surgical anesthesia and postoperative analgesia in cardiac implantable electronic devices (CIED) insertion. The aim of this study was to evaluate the feasibility of the pectoral nerves (PECS) II block for CIED insertion.

Methods

PECS II blocks were performed on the left side using the ultrasound‐guided single injection technique in all patients. The primary outcome for feasibility was the percentage of the cases completed without intraoperative additional local anesthesia. Secondary outcomes were the amount of intraoperative additional local anesthetic, intraoperative opioid requirement, postoperative pain scores, first requirement for postoperative analgesia, postoperative analgesic consumption, patient satisfaction, and block‐related complications.

Results

Of the total 30 patients, 19 (63.3%) required intraoperative additional local anesthetic. The median (IQR [range]) volume of the additional local anesthetic used was 7 (4‐10 [2.5‐12]) mL. Two patients needed additional IV analgesics in the first 24 h postoperatively. No statistically significant differences were determined between the patients requiring and not requiring intraoperative additional local anesthetic in respect of age, gender, duration of surgery, block performance time, and hospital stay. A total of 26 (86.6%) patients reported a high level of satisfaction with the procedure.

Conclusions

PECS II block for cardiac electronic implantable device insertion provides effective postoperative analgesia for at least 24 h. Although PECS II block alone could not provide complete surgical anesthesia in the majority of the patients, when combined with supplementary local anesthetic, contributes to a smooth intraoperative course for patients.

Subjects

MeSH terms (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialNerve BlockProsthesis ImplantationThoracic NervesHumansPilot ProjectsMaleFemaleAgedPostoperative PainMiddle AgedFeasibility StudiesPatient SatisfactionUltrasonography, InterventionalAnesthetics, Local

Author keywords

Cardiac implantable electronic deviceanalgesiaanesthesiaintraoperativepectoral nerves blockpostoperative

Substances

Anesthetics, Local

Authors and institutions

  • Department of Anesthesiology and Reanimation, University of Health Sciences Antalya Training and Research Hospital, Antalya, Turkey.
  • Department of Anesthesiology and Reanimation, Istinye University Faculty of Medicine, Istanbul, Turkey.
  • Department of Cardiology, University of Health Sciences Antalya Training and Research Hospital, Antalya, Turkey.

ORCID profiles: Mustafa Kilin, Ali Sait Kavakli, Arzu Karaveli, Tayfun Sugur, Gorkem Kus, Goksel Cagirci, Sakir Arslan

Cite

APA

Kilin, M., Kavakli, A. S., Karaveli, A., Sugur, T., Kus, G., Cagirci, G., & Arslan, S. (2023). PECS II block for cardiac implantable electronic device insertion: A pilot study. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14811

Vancouver

Kilin M, Kavakli AS, Karaveli A, Sugur T, Kus G, Cagirci G, et al. PECS II block for cardiac implantable electronic device insertion: A pilot study. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14811

BibTeX
@article{Kilin2023,
  author = {Kilin, Mustafa and Kavakli, Ali Sait and Karaveli, Arzu and Sugur, Tayfun and Kus, Gorkem and Cagirci, Goksel and Arslan, Sakir},
  title = {PECS II block for cardiac implantable electronic device insertion: A pilot study},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14811}
}
Start for free →