Safety and Efficiency of Cephalic Vein Puncture by Modified Seldinger Technique Compared to Subclavian Vein Puncture for Cardiac Implantable Electronic Devices
Clinical Cardiology · 2024
DOI: 10.1002/clc.24327 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Cardiology, 2024. Verfasst von Marie-Christine Weidauer und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Helios Klinikum Pirna, Pirna, Germany. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Punctures, Subclavian Vein, Pacemaker, Artificial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Introduction
The establishment of venous access is one of the driving factors for complications during implantation of pacemakers and defibrillators (cardiac implantable electronic devices [CIED]). Recently, a novel approach of accessing the cephalic vein for CIED by cephalic vein puncture (CVP) using a modified Seldinger technique has been described, promising high success rates and simplified handling with steeper learning curves. In this single‐center registry, we analyzed the safety and efficiency of CVP to SVP access after defining CVP as the primary access route in our center.
Methods
A total of 229 consecutive patients receiving a CIED were included in the registry. Sixty‐one patients were implanted by primary or bail‐out SVP; 168 patients received primary cephalic preparation and CVP was performed when possible, using a hydrophilic transradial sheath.
Results
Implantation of at least one lead via CVP was successful in 151 of 168 patients (90%), and implantation of all leads was possible in 122 of 168 patients (72.6%). Total implantation times and fluoroscopy times and doses did not differ between CVP and SVP implantations. Pneumothorax occurred in 0/122 patients implanted via CVP alone, but 8/107 (7.5%) patients received at least one lead via SVP.
Conclusion
Our data confirms high success rates of the CVP for CIED implantation. Moreover, this method can be used without significantly prolonging the total procedure time or applying fluoroscopy dose compared to the highly efficient SVP while showing lower overall complication rates.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Helios Klinikum Pirna, Pirna, Germany.
- Department of Cardiology, TU Dresden Campus Chemnitz-MEDiC, Klinikum Chemnitz, Chemnitz, Germany.
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Weidauer, M. C., Knüpfer, E., Lottermoser, J., Alkomi, U., Schoen, S., Wunderlich, C., Christoph, M., & Francke, A. (2024). Safety and Efficiency of Cephalic Vein Puncture by Modified Seldinger Technique Compared to Subclavian Vein Puncture for Cardiac Implantable Electronic Devices. Clinical Cardiology. https://doi.org/10.1002/clc.24327
Vancouver
Weidauer MC, Knüpfer E, Lottermoser J, Alkomi U, Schoen S, Wunderlich C, et al. Safety and Efficiency of Cephalic Vein Puncture by Modified Seldinger Technique Compared to Subclavian Vein Puncture for Cardiac Implantable Electronic Devices. Clinical Cardiology. 2024. doi:10.1002/clc.24327
BibTeX
@article{Weidauer2024,
author = {Weidauer, Marie-Christine and Knüpfer, Enzo and Lottermoser, Jörg and Alkomi, Usama and Schoen, Steffen and Wunderlich, Carsten and Christoph, Marian and Francke, Alexander},
title = {Safety and Efficiency of Cephalic Vein Puncture by Modified Seldinger Technique Compared to Subclavian Vein Puncture for Cardiac Implantable Electronic Devices},
journal = {Clinical Cardiology},
year = {2024},
doi = {10.1002/clc.24327}
}
EUVIMED