EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Safety and Efficiency of Cephalic Vein Puncture by Modified Seldinger Technique Compared to Subclavian Vein Puncture for Cardiac Implantable Electronic Devices

Marie-Christine Weidauer, Enzo Knüpfer, Jörg Lottermoser, Usama Alkomi, Steffen Schoen, Carsten Wunderlich, Marian Christoph, Alexander Francke

Clinical Cardiology · 2024

DOI: 10.1002/clc.24327 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Cardiology, 2024. Verfasst von Marie-Christine Weidauer und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Helios Klinikum Pirna, Pirna, Germany. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Punctures, Subclavian Vein, Pacemaker, Artificial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The establishment of venous access is one of the driving factors for complications during implantation of pacemakers and defibrillators (cardiac implantable electronic devices [CIED]). Recently, a novel approach of accessing the cephalic vein for CIED by cephalic vein puncture (CVP) using a modified Seldinger technique has been described, promising high success rates and simplified handling with steeper learning curves. In this single‐center registry, we analyzed the safety and efficiency of CVP to SVP access after defining CVP as the primary access route in our center.

Methods

A total of 229 consecutive patients receiving a CIED were included in the registry. Sixty‐one patients were implanted by primary or bail‐out SVP; 168 patients received primary cephalic preparation and CVP was performed when possible, using a hydrophilic transradial sheath.

Results

Implantation of at least one lead via CVP was successful in 151 of 168 patients (90%), and implantation of all leads was possible in 122 of 168 patients (72.6%). Total implantation times and fluoroscopy times and doses did not differ between CVP and SVP implantations. Pneumothorax occurred in 0/122 patients implanted via CVP alone, but 8/107 (7.5%) patients received at least one lead via SVP.

Conclusion

Our data confirms high success rates of the CVP for CIED implantation. Moreover, this method can be used without significantly prolonging the total procedure time or applying fluoroscopy dose compared to the highly efficient SVP while showing lower overall complication rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantablePuncturesSubclavian VeinPacemaker, ArtificialRegistriesHumansMaleFemaleAgedTreatment OutcomeCatheterization, Central VenousMiddle AgedProsthesis ImplantationRetrospective StudiesAged, 80 and overTime Factors

Stichwörter der Autor:innen

cardiac implantable electronic devicescephalic vein puncturesubclavian vein puncture

Autor:innen und Institutionen

  • Department of Cardiology, Helios Klinikum Pirna, Pirna, Germany.
  • Department of Cardiology, TU Dresden Campus Chemnitz-MEDiC, Klinikum Chemnitz, Chemnitz, Germany.

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Weidauer, M. C., Knüpfer, E., Lottermoser, J., Alkomi, U., Schoen, S., Wunderlich, C., Christoph, M., & Francke, A. (2024). Safety and Efficiency of Cephalic Vein Puncture by Modified Seldinger Technique Compared to Subclavian Vein Puncture for Cardiac Implantable Electronic Devices. Clinical Cardiology. https://doi.org/10.1002/clc.24327

Vancouver

Weidauer MC, Knüpfer E, Lottermoser J, Alkomi U, Schoen S, Wunderlich C, et al. Safety and Efficiency of Cephalic Vein Puncture by Modified Seldinger Technique Compared to Subclavian Vein Puncture for Cardiac Implantable Electronic Devices. Clinical Cardiology. 2024. doi:10.1002/clc.24327

BibTeX
@article{Weidauer2024,
  author = {Weidauer, Marie-Christine and Knüpfer, Enzo and Lottermoser, Jörg and Alkomi, Usama and Schoen, Steffen and Wunderlich, Carsten and Christoph, Marian and Francke, Alexander},
  title = {Safety and Efficiency of Cephalic Vein Puncture by Modified Seldinger Technique Compared to Subclavian Vein Puncture for Cardiac Implantable Electronic Devices},
  journal = {Clinical Cardiology},
  year = {2024},
  doi = {10.1002/clc.24327}
}
Kostenlos starten →