EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Left bundle branch area pacing (LBBAP) Auto Threshold algorithms Evaluation for Conduction System Pacing: The LATECS pilot Trial

Chiara Ghiglieno iD, Gabriele Dell'Era, Alessandro Veroli, Federica De Vecchi, Matteo Santagostino, Stefano Porcellini, Giuseppe Patti

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14777 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Pacing and Clinical Electrophysiology, 2023. Verfasst von Chiara Ghiglieno und 6 weiteren Autor:innen. Beteiligte Einrichtung: Clinica Cardiologica, Dipartimento Toraco-Cardio-Vascolare, Ospedale Maggiore della Carità, Novara, Italy. Hauptthemen laut MEDLINE: Heart Conduction System, Ventricular Septum. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Automated threshold measurements (ATM) and output adaptation improved safety and follow‐up of cardiac implantable devices (CIED) in the last years. These algorithms were validated for conventional cardiac pacing; however, they were not suitable for permanent His Pacing. Left bundle branch area pacing (LBBAP) is an emerging technique to obtain physiologic cardiac stimulation; we tried to assess if ATM could be applied to this setting.

Methods

Consecutive patients receiving ATM‐capable CIED and LBBAP in our hospital were enrolled in this prospective, observational trial; they were evaluated 3 months after implant, comparing pacing thresholds manually assessed and obtained via ATM. Subsequent remote follow‐up was carried on when available.

Results

Forty‐five patients were enrolled. ATM for LBBAP lead provided consistent results in all the patients and was therefore activated; mean value of manually obtained LBBAP capture threshold was 0.66 ± 0.19 V versus ATM of 0.64 ± 0.19 V. TOST analysis showed equivalence of the two measures ( p = .66). At subsequent follow‐up (mean follow up 7.7 ± 3.2 months), ATM was effective in assessing pacing thresholds and no clinical adverse event was observed.

Conclusions

ATM algorithms proved equivalent to manual testing in determining capture threshold and were reliably employed in patients receiving LBBAP CIED.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Conduction SystemVentricular SeptumHumansPilot ProjectsProspective StudiesCardiac Conduction System DiseaseAlgorithmsElectrocardiographyCardiac Pacing, ArtificialBundle of HisTreatment Outcome

Stichwörter der Autor:innen

LBBAPauto threshold managementcardiac implantable devices follow-upleft bundle branch area pacingremote monitoringsystem pacing

Autor:innen und Institutionen

  • Clinica Cardiologica, Dipartimento Toraco-Cardio-Vascolare, Ospedale Maggiore della Carità, Novara, Italy.
  • Università del Piemonte Orientale Amedeo Avogadro, Novara, Italy.

ORCID-Profile: Chiara Ghiglieno

Zitieren

APA

Ghiglieno, C., Dell'Era, G., Veroli, A., De Vecchi, F., Santagostino, M., Porcellini, S., & Patti, G. (2023). Left bundle branch area pacing (LBBAP) Auto Threshold algorithms Evaluation for Conduction System Pacing: The LATECS pilot Trial. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14777

Vancouver

Ghiglieno C, Dell'Era G, Veroli A, De Vecchi F, Santagostino M, Porcellini S, et al. Left bundle branch area pacing (LBBAP) Auto Threshold algorithms Evaluation for Conduction System Pacing: The LATECS pilot Trial. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14777

BibTeX
@article{Ghiglieno2023,
  author = {Ghiglieno, Chiara and Dell'Era, Gabriele and Veroli, Alessandro and De Vecchi, Federica and Santagostino, Matteo and Porcellini, Stefano and Patti, Giuseppe},
  title = {Left bundle branch area pacing (LBBAP) Auto Threshold algorithms Evaluation for Conduction System Pacing: The LATECS pilot Trial},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14777}
}
Kostenlos starten →