EUVIMEDEUVIMED entdecken
BeobachtungsstudieMultizentrische Studie

Ablate and pace: Comparison of outcomes between conduction system pacing and biventricular pacing

Pietro Palmisano iD, Matteo Ziacchi, Gabriele Dell'Era, Paolo Donateo, Ernesto Ammendola, Vittorio Aspromonte, Pier Lugi Pellegrino, Giuseppe Del Giorno, Giovanni Coluccia, Lorenzo Bartoli, Giuseppe Patti, Jacopo Senes und 7 weitere

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14813 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Pacing and Clinical Electrophysiology, 2023. Verfasst von Pietro Palmisano und 18 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Unit, "Card. G. Panico" Hospital, Tricase, Italy. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Heart Failure. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Conduction system pacing (CSP), including His‐bundle pacing (HBP) and left bundle branch area pacing (LBBAP), have been proposed as alternatives to biventricular pacing (BVP) in patients scheduled for ablate and pace (A&P) strategy. The aim of this study was to compare the clinical outcomes, including the rate and nature of device‐related complications, between BVP and CSP in a cohort of patients undergoing A&P.

Methods

Prospective, multicenter, observational study, enrolling consecutive patients undergoing A&P. The risk of device‐related complications and of heart failure (HF) hospitalization was prospectively assessed.

Results

A total of 373 patients (75.3 ± 8.7 years, 53.9% male, 68.9% with NYHA class ≥III) were enrolled: 263 with BVP, 68 with HBP, and 42 with LBBAP. Baseline characteristics of the three groups were similar. Compared to BVP and HBP, LBBAP was associated with the shortest mean procedural and fluoroscopy times and with the lowest acute capture thresholds (all p < .05). At 12‐month follow‐up LBBAP maintained the lowest capture thresholds and showed the longest estimated residual battery longevity (all p < .05). At 12‐months follow‐up the three study groups showed a similar risk of device‐related complications (5.7%, 4.4%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .650), and of HF hospitalization (2.7%, 1.5%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .850).

Conclusions

In the setting of A&P, CSP is a feasible pacing modality, with a midterm safety profile comparable to BVP. LBBAP offers the advantage of reducing procedural times and obtaining lower and stable capture thresholds, with a positive impact on the device longevity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Resynchronization TherapyHeart FailureHumansMaleFemaleProspective StudiesHeart Conduction SystemCardiac Conduction System DiseaseElectric Power SuppliesBundle of HisTreatment OutcomeElectrocardiographyCardiac Pacing, Artificial

Stichwörter der Autor:innen

AV node ablationHis bundle pacingablate and paceatrial fibrillationbiventricular pacingcatheter ablationconduction system pacingheart failureleft bundle branch area pacingnarrow QRS

Autor:innen und Institutionen

  • Cardiology Unit, "Card. G. Panico" Hospital, Tricase, Italy.
  • Institute of Cardiology, University of Bologna, S. Orsola-Malpighi University Hospital, Bologna, Italy.
  • Division of Cardiology, University of Eastern Piedmont, Maggiore della Carità Hospital, Novara, Italy.
  • Department of Cardiology, Arrhythmology Center, Lavagna, Italy.
  • Department of Cardiology, Monaldi Hospital, Second University of Naples, Naples, Italy.
  • Cardiology-Coronary Care Unit, Pugliese-Ciaccio Hospital, Catanzaro, Italy.

ORCID-Profile: Pietro Palmisano

Zitieren

APA

Palmisano, P., Ziacchi, M., Dell'Era, G., Donateo, P., Ammendola, E., Aspromonte, V., Pellegrino, P. L., Del Giorno, G., Coluccia, G., Bartoli, L., Patti, G., Senes, J., Parlavecchio, A., Di Fraia, F., Brunetti, N. D., Carbone, A., Nigro, G., Biffi, M., & Accogli, M. (2023). Ablate and pace: Comparison of outcomes between conduction system pacing and biventricular pacing. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14813

Vancouver

Palmisano P, Ziacchi M, Dell'Era G, Donateo P, Ammendola E, Aspromonte V, et al. Ablate and pace: Comparison of outcomes between conduction system pacing and biventricular pacing. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14813

BibTeX
@article{Palmisano2023,
  author = {Palmisano, Pietro and Ziacchi, Matteo and Dell'Era, Gabriele and Donateo, Paolo and Ammendola, Ernesto and Aspromonte, Vittorio and Pellegrino, Pier Lugi and Del Giorno, Giuseppe and Coluccia, Giovanni and Bartoli, Lorenzo and Patti, Giuseppe and Senes, Jacopo and Parlavecchio, Antonio and Di Fraia, Francesco and Brunetti, Natale Daniele and Carbone, Angelo and Nigro, Gerardo and Biffi, Mauro and Accogli, Michele},
  title = {Ablate and pace: Comparison of outcomes between conduction system pacing and biventricular pacing},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14813}
}
Kostenlos starten →