EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Left Ventricular Ejection Fraction and Incident Cardiac Conduction Dysfunction: Exploring the Mediating Effects of Electrophysiological Parameters

Qie Zhang iD, Feilong Zhang iD, Yuhao Hu, Jinfeng Wang, Xinlin Yang, Zhou Du, Yuting Chen, Jiran Shen, Ronghui Yu iD

Annals of Noninvasive Electrocardiology · 2026

DOI: 10.1111/anec.70146 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Noninvasive Electrocardiology, 2026. Verfasst von Qie Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, National Cardiovascular Disease Regional Center for Anhui, The First Affiliated Hospital of Anhui Medical University, Hefei…. Hauptthemen laut MEDLINE: Stroke Volume, Electrocardiography, Ventricular Dysfunction, Left, Cardiac Conduction System Disease. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Anhui Provincial Department of Science and Technology, Anhui Provincial Department of Education, Lvliang Municipal Bureau of Science and Technology, Shanxi Province, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Population‐based evidence on the predictive role of left ventricular ejection fraction (LVEF) in incident Cardiac Conduction Dysfunction (CCD) and the mediating effects of electrophysiological parameters remains understudied. This study aimed to characterize the relationship between LVEF and incident CCD and explore the potential mediating effects of electrophysiological parameters.

Methods

This prospective cohort study included 32,398 participants (96.6% White ethnicity) from the UK Biobank with analyzable LVEF and electrocardiogram data. Incident CCD was defined as the first occurrence of atrioventricular block, left bundle branch block, or other conduction disorders. Stepwise backward Cox regression and sensitivity analyses evaluated the association between LVEF and CCD. Additionally, mediation analysis was performed to examine QRS duration, PQ interval, and corrected QT interval as potential mediators.

Results

During a mean follow‐up of 6.96 ± 1.63 years, 484 incident CCD cases were identified. LVEF was an independent predictor of incident CCD, with each 1‐standard deviation increase in LVEF associated with a 17% reduction in risk (adjusted hazard ratio, 0.83; 95% confidence interval, 0.77–0.89; p < 0.001). Sensitivity analyses across LVEF thresholds, competing risks, and exclusion of early events confirmed the robustness of these findings. Mediation analysis showed that PQ interval mediated 6% ( p < 0.001), QRS duration mediated 17% ( p < 0.001), and corrected QT interval mediated −3% ( p = 0.002) of the total effect.

Conclusion

LVEF is independently associated with incident CCD, with electrophysiological parameters potentially explaining part of this association. These findings underscore the clinical relevance of myocardial mechano‐electrical coupling in large‐scale population settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Stroke VolumeElectrocardiographyVentricular Dysfunction, LeftCardiac Conduction System DiseaseHeart Conduction SystemHumansFemaleMaleProspective StudiesMiddle AgedAgedIncidenceUnited Kingdom

Stichwörter der Autor:innen

electrophysiological parametersincident cardiac conduction dysfunctionleft ventricular ejection fractionmediation factorspredictive value

Autor:innen und Institutionen

  • Department of Cardiology, National Cardiovascular Disease Regional Center for Anhui, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China.
  • Department of Medical Research, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, China.

ORCID-Profile: Qie Zhang, Feilong Zhang, Ronghui Yu

Förderung

  • Anhui Provincial Department of Science and Technology
  • Anhui Provincial Department of Education
  • Lvliang Municipal Bureau of Science and Technology, Shanxi Province, China

Zitieren

APA

Zhang, Q., Zhang, F., Hu, Y., Wang, J., Yang, X., Du, Z., Chen, Y., Shen, J., & Yu, R. (2026). Left Ventricular Ejection Fraction and Incident Cardiac Conduction Dysfunction: Exploring the Mediating Effects of Electrophysiological Parameters. Annals of Noninvasive Electrocardiology. https://doi.org/10.1111/anec.70146

Vancouver

Zhang Q, Zhang F, Hu Y, Wang J, Yang X, Du Z, et al. Left Ventricular Ejection Fraction and Incident Cardiac Conduction Dysfunction: Exploring the Mediating Effects of Electrophysiological Parameters. Annals of Noninvasive Electrocardiology. 2026. doi:10.1111/anec.70146

BibTeX
@article{Zhang2026,
  author = {Zhang, Qie and Zhang, Feilong and Hu, Yuhao and Wang, Jinfeng and Yang, Xinlin and Du, Zhou and Chen, Yuting and Shen, Jiran and Yu, Ronghui},
  title = {Left Ventricular Ejection Fraction and Incident Cardiac Conduction Dysfunction: Exploring the Mediating Effects of Electrophysiological Parameters},
  journal = {Annals of Noninvasive Electrocardiology},
  year = {2026},
  doi = {10.1111/anec.70146}
}
Kostenlos starten →