EUVIMEDDécouvrir EUVIMED
Crossref

Residual leak following left atrial appendage occlusion with lariat closed with amplatzer PFO occluder device

Danish Bawa, Adnan Ahmed, Douglas Darden, Dhanunjaya Lakkireddy

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14669 ↗

At a glance

Journal article in Pacing and Clinical Electrophysiology, 2023. Written by Danish Bawa and 3 co-authors. Institution: Kansas City Heart Rhythm Institute, Overland Park, Kansas, USA. Major MEDLINE topics: Atrial Appendage, Atrial Fibrillation, Stroke, Septal Occluder Device. Cited 1 times so far (Crossref); 10 references.

RésuméSubjectsRéférences bibliographiquesCiteRelated studies

Abstract (original language)

Background

Leaks from incomplete ligation of the left atrial appendage (LAA) following closure with Lariat device are not uncommon and associated with higher stroke rate. Clinical Vignette This clinical vignette highlights a procedure of closure of residual leak following closure with Lariat device. There was a persistent central leak of 3–4 mm with bidirectional flow, confirmed on TEE. The Amplatzer Talisman PFO Occluder was chosen for the closure of the leak because of its asymmetric discs with a smaller distal disc and expandable waist.

Conclusion

In situations where the options are limited for PDL closure, such as the one described in this vignette, it is paramount to continue to find innovative solutions to emerging challenges in transcatheter interventions.

Subjects

MeSH terms (MEDLINE)

Atrial AppendageAtrial FibrillationStrokeSeptal Occluder DeviceHumansTreatment OutcomeEchocardiography, TransesophagealCardiac Catheterization

Author keywords

amplatzer PFO occluder devicelariat deviceleft atrial appendage closureresidual leak

Authors and institutions

  • Kansas City Heart Rhythm Institute, Overland Park, Kansas, USA.

Cite

APA

Bawa, D., Ahmed, A., Darden, D., & Lakkireddy, D. (2023). Residual leak following left atrial appendage occlusion with lariat closed with amplatzer PFO occluder device. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14669

Vancouver

Bawa D, Ahmed A, Darden D, Lakkireddy D. Residual leak following left atrial appendage occlusion with lariat closed with amplatzer PFO occluder device. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14669

BibTeX
@article{Bawa2023,
  author = {Bawa, Danish and Ahmed, Adnan and Darden, Douglas and Lakkireddy, Dhanunjaya},
  title = {Residual leak following left atrial appendage occlusion with lariat closed with amplatzer PFO occluder device},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14669}
}
Start for free →