EUVIMEDEUVIMED entdecken
Crossref

Residual leak following left atrial appendage occlusion with lariat closed with amplatzer PFO occluder device

Danish Bawa, Adnan Ahmed, Douglas Darden, Dhanunjaya Lakkireddy

Pacing and Clinical Electrophysiology · 2023

DOI: 10.1111/pace.14669 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2023. Verfasst von Danish Bawa und 3 weiteren Autor:innen. Beteiligte Einrichtung: Kansas City Heart Rhythm Institute, Overland Park, Kansas, USA. Hauptthemen laut MEDLINE: Atrial Appendage, Atrial Fibrillation, Stroke, Septal Occluder Device. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Leaks from incomplete ligation of the left atrial appendage (LAA) following closure with Lariat device are not uncommon and associated with higher stroke rate. Clinical Vignette This clinical vignette highlights a procedure of closure of residual leak following closure with Lariat device. There was a persistent central leak of 3–4 mm with bidirectional flow, confirmed on TEE. The Amplatzer Talisman PFO Occluder was chosen for the closure of the leak because of its asymmetric discs with a smaller distal disc and expandable waist.

Conclusion

In situations where the options are limited for PDL closure, such as the one described in this vignette, it is paramount to continue to find innovative solutions to emerging challenges in transcatheter interventions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial AppendageAtrial FibrillationStrokeSeptal Occluder DeviceHumansTreatment OutcomeEchocardiography, TransesophagealCardiac Catheterization

Stichwörter der Autor:innen

amplatzer PFO occluder devicelariat deviceleft atrial appendage closureresidual leak

Autor:innen und Institutionen

  • Kansas City Heart Rhythm Institute, Overland Park, Kansas, USA.

Zitieren

APA

Bawa, D., Ahmed, A., Darden, D., & Lakkireddy, D. (2023). Residual leak following left atrial appendage occlusion with lariat closed with amplatzer PFO occluder device. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.14669

Vancouver

Bawa D, Ahmed A, Darden D, Lakkireddy D. Residual leak following left atrial appendage occlusion with lariat closed with amplatzer PFO occluder device. Pacing and Clinical Electrophysiology. 2023. doi:10.1111/pace.14669

BibTeX
@article{Bawa2023,
  author = {Bawa, Danish and Ahmed, Adnan and Darden, Douglas and Lakkireddy, Dhanunjaya},
  title = {Residual leak following left atrial appendage occlusion with lariat closed with amplatzer PFO occluder device},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2023},
  doi = {10.1111/pace.14669}
}
Kostenlos starten →