EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Superior patient‐reported clinical outcomes after patient‐individual total knee arthroplasty compared with off‐the‐shelf robotic‐assisted total knee arthroplasty in valgus knee phenotypes

Lars-Rene Tuecking iD, Peter Savov iD, Mara Hold iD, Ricarda Stauss iD, Henning Windhagen iD, Max Ettinger iD

Knee Surgery, Sports Traumatology, Arthroscopy · 2026-11 · 34 (11) · 4125-4132

DOI: 10.1002/ksa.70399 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 16.04.2026. Verfasst von Lars-Rene Tuecking und 5 weiteren Autor:innen. Beteiligte Einrichtung: Hannover Medical School, Clinic of Orthopaedic Surgery in Diakovere Annastift, Hannover, Germany. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Patient Reported Outcome Measures, Robotic Surgical Procedures, Knee Joint. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Erwin Roewer Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare early patient‐reported clinical outcomes of patient‐individual total knee arthroplasty (TKA) with individualized trochlear design versus robotic‐assisted TKA using off‐the‐shelf implants in patients with valgus knee phenotypes and pronounced femoral valgus (lateral distal femoral angle [LDFA] < 85°) at 3 and 12 months postoperatively in a prospective matched case–control study.

Methods

This prospective matched case–control study based on predefined anatomical criteria included 42 patients who underwent primary TKA between October 2021 and October 2023. Twenty‐one patients received patient‐individual posterior‐stabilized implants. Twenty‐one matched controls underwent robotic‐assisted TKA with off‐the‐shelf implants. All procedures followed restricted kinematic alignment (KA) principles with valgus undercorrection. Primary outcomes were patient‐reported scores (Forgotten Joint Score [FJS], Kujala Score, Oxford Knee Score [OKS] and the Western Ontario and McMaster Universities Arthritis Index [WOMAC]), assessed preoperatively and at 3 and 12 months.

Results

Both groups demonstrated comparable preoperative clinical status and comparable degrees of preoperative valgus deformity, with no significant differences in hip–knee–ankle angle (HKA, 185.6 ± 6.3° vs. 188.8 ± 4.1°; p = 0.060) or mechanical LDFA (84.0 ± 0.9° vs. 83.7 ± 1.2°; p = 0.261). At 3 and 12 months, patient‐individual total knee arthroplasty (pTKA) demonstrated significantly better scores across all patient‐reported outcome measures (PROMs) ( p < 0.05). The largest difference was observed in the Kujala score at 12 months (79.5 ± 12.8 vs. 59.7 ± 19.0, p = 0.001). FJS improved more rapidly in the pTKA group (from 9.0 to 49.1 at 3 months, and 52.5 at 12 months) compared to robotic‐assisted total knee arthroplasty (rTKA) (26.9 and 36.0, respectively). One revision for suspected infection occurred in the pTKA cohort; none were reported after rTKA.

Conclusions

Patient‐individual TKA with individualized trochlear design achieved superior early functional outcomes compared to robotic‐assisted TKA with standard implants in severe valgus morphotypes. Individualized trochlear orientation may improve patellofemoral mechanics and facilitate faster recovery in patients with severe femoral valgus. Level of Evidence Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneePatient Reported Outcome MeasuresRobotic Surgical ProceduresKnee JointKnee ProsthesisOsteoarthritis, KneeHumansFemaleAgedProspective StudiesMaleCase-Control StudiesMiddle AgedProsthesis DesignPhenotype

Stichwörter der Autor:innen

CPAKpatient‐individualrobotic‐assistedtotal knee arthroplastyvalgus

Autor:innen und Institutionen

  • Hannover Medical School, Clinic of Orthopaedic Surgery in Diakovere Annastift, Hannover, Germany.
  • Department of Orthopaedic and Trauma Surgery, Pius Hospital, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany.

ORCID-Profile: Lars-Rene Tuecking, Peter Savov, Mara Hold, Ricarda Stauss, Henning Windhagen, Max Ettinger

Förderung

  • Erwin Roewer Stiftung

Zitieren

APA

Tuecking, L. R., Savov, P., Hold, M., Stauss, R., Windhagen, H., & Ettinger, M. (2026). Superior patient‐reported clinical outcomes after patient‐individual total knee arthroplasty compared with off‐the‐shelf robotic‐assisted total knee arthroplasty in valgus knee phenotypes. Knee Surgery, Sports Traumatology, Arthroscopy, 34(11), 4125-4132. https://doi.org/10.1002/ksa.70399

Vancouver

Tuecking LR, Savov P, Hold M, Stauss R, Windhagen H, Ettinger M. Superior patient‐reported clinical outcomes after patient‐individual total knee arthroplasty compared with off‐the‐shelf robotic‐assisted total knee arthroplasty in valgus knee phenotypes. Knee Surgery, Sports Traumatology, Arthroscopy. 2026;34(11):4125-4132. doi:10.1002/ksa.70399

BibTeX
@article{Tuecking2026,
  author = {Tuecking, Lars-Rene and Savov, Peter and Hold, Mara and Stauss, Ricarda and Windhagen, Henning and Ettinger, Max},
  title = {Superior patient‐reported clinical outcomes after patient‐individual total knee arthroplasty compared with off‐the‐shelf robotic‐assisted total knee arthroplasty in valgus knee phenotypes},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2026},
  volume = {34},
  number = {11},
  pages = {4125--4132},
  doi = {10.1002/ksa.70399}
}
Kostenlos starten →