Journal article in Orthopaedic Surgery, published online on 2026-03-06. Written by Zhao Xiao-Feng and 5 co-authors. Institution: Department of Orthopaedics, The Second Hospital of Shanxi Medical University, Taiyuan, China. Major MEDLINE topics: Bone Plates, Cervical Vertebrae, Bone Screws, Spinal Fusion. 29 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: the Shanxi Province Science and Technology Achievement Transformation Guidance Special Project.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Background

Plate‐screw fixation systems have been widely applied in anterior cervical decompression surgery, yet the design of the plates themselves and a series of severe complications arising therefrom have attracted increasing attention from clinicians and scholars. In this study, a novel anterior cervical plate system was designed and subjected to biomechanical testing.

Methods

Twelve fresh goat cadaveric specimens were used. A high‐precision digital grating displacement sensor system was used to compare the stability, fatigue resistance, and pull‐out strength of the novel PRUNUS plate‐screw system to those of the Atlantis plate‐screw system in destabilized cervical spines.

Results

The biomechanical test results revealed that the novel PRUNUS plate‐screw system provided equivalent three‐dimensional stability to that of the Atlantis system, ensuring immediate postoperative stability of the cervical spine after anterior cervical internal fixation and meeting the requirements for rigid internal fixation. In addition, the PRUNUS system exhibited a similar fatigue life and fatigue strength to those of the Atlantis system, which was sufficient to maintain cervical stability after anterior interbody fusion, confirming the long‐term safety and efficacy of the PRUNUS system in vivo. The PRUNUS system also showed superior overall fixation and locking performance.

Conclusion

The novel PRUNUS plate‐screw system possesses excellent biomechanical properties and provides effective stabilization for the cervical spine.

Subjects

MeSH terms (MEDLINE)

Bone PlatesCervical VertebraeBone ScrewsSpinal FusionAnimalsBiomechanical PhenomenaGoatsCadaverMaterials Testing

Author keywords

Anterior cervical spine plateBiomechanicsPRUNUS spine plate system

Authors and institutions

  • Department of Orthopaedics, The Second Hospital of Shanxi Medical University, Taiyuan, China.

ORCID profiles: Zhao Xiao-Feng, Xue Ning-Ning

Funding

  • the Shanxi Province Science and Technology Achievement Transformation Guidance Special Project

Cite

APA

Xiao-Feng, Z., Ning-Ning, X., Xiang-Dong, L., Xiang, L., Zhi-Feng, F., & Bin, Z. (2026). Development and Biomechanical Study of the Novel PRUNUS Plate‐Screw System. Orthopaedic Surgery, 18(4), 662-669. https://doi.org/10.1111/os.70273

Vancouver

Xiao-Feng Z, Ning-Ning X, Xiang-Dong L, Xiang L, Zhi-Feng F, Bin Z. Development and Biomechanical Study of the Novel PRUNUS Plate‐Screw System. Orthopaedic Surgery. 2026;18(4):662-669. doi:10.1111/os.70273

BibTeX
@article{XiaoFeng2026,
  author = {Xiao-Feng, Zhao and Ning-Ning, Xue and Xiang-Dong, Lu and Xiang, Li and Zhi-Feng, Fan and Bin, Zhao},
  title = {Development and Biomechanical Study of the Novel PRUNUS Plate‐Screw System},
  journal = {Orthopaedic Surgery},
  year = {2026},
  volume = {18},
  number = {4},
  pages = {662--669},
  doi = {10.1111/os.70273}
}
Start for free →