Implantation Accuracy of Custom‐Made Acetabular Components With Iliac Stem Fixation for Large Bone Defects in Hip Revision Surgery
Orthopaedic Surgery · 2025
DOI: 10.1111/os.70186 ↗At a glance
Journal article in Orthopaedic Surgery, 2025. Written by Timo A Nees and 7 co-authors. Institution: Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany. Major MEDLINE topics: Arthroplasty, Replacement, Hip, Acetabulum, Hip Prosthesis, Reoperation. Cited 2 times so far (Crossref); 32 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Objectives
The treatment of extensive acetabular bone defects presents significant challenges in revision total hip arthroplasty (rTHA). Custom‐made implants, tailored to patient‐specific anatomy via 3D printing, offer potential advantages regarding implant stability and alignment. Precise positioning of these large‐volume implants is crucial for primary stability and long‐term fixation, but can be surgically demanding, especially when intramedullary iliac press‐fit stems are used. In contrast to triflange custom‐made implants, data on the implantation accuracy of custom‐made acetabular components with iliac stem fixation remain limited. This study aimed to assess the accuracy of implant positioning by comparing preoperatively planned component positions with postoperative radiographic outcomes, focusing on anteversion (AV), inclination (INCL), and the center of rotation (CoR).
Methods
In this retrospective cohort study, 24 patients with large acetabular defects (Paprosky ≥ 3A) underwent rTHA with custom‐made acetabular components with intramedullary press‐fit iliac stem fixation between November 2022 and April 2024. Implantation accuracy was evaluated by comparing the planned positions on preoperative CT scans with the actual implant positions observed on 6‐week postoperative radiographs using a previously validated methodology. Discrepancies in AV, INCL, and the CoR were analyzed.
Results
A high degree of alignment with preoperative plans was observed. The mean postoperative AV was 9.96° ± 6.4° (planned: 10.2°), and the mean INCL was 46.3° ± 3.2° (planned: 44.6°). The deviations were minor (Δ AV: −0.25°, Δ INCL: 1.7°), confirming the precision of implant placement. Four implants had CoR deviations exceeding 5 mm cranially (mean cranial shift: 1.77 ± 3.97 mm), and five exceeded 5 mm laterally. Most deviations were within clinically acceptable ranges.
Conclusions
Our findings demonstrate that custom‐made acetabular components with iliac stem fixation can be implanted with high accuracy. Moreover, our results support the use of standard radiographs for the postoperative assessment of implant positioning precision. This study provides valuable insights into the accuracy of implant placement in complex rTHA cases, highlighting the role of patient‐specific implant technologies in enhancing surgical outcomes.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Orthopaedics, Heidelberg University Hospital, Heidelberg, Germany.
ORCID profiles: Tobias Reiner
Cite
APA
Nees, T. A., Hariri, M., Müller, C. T., Innmann, M. M., Spranz, D. M., Westhauser, F., Walker, T., & Reiner, T. (2025). Implantation Accuracy of Custom‐Made Acetabular Components With Iliac Stem Fixation for Large Bone Defects in Hip Revision Surgery. Orthopaedic Surgery. https://doi.org/10.1111/os.70186
Vancouver
Nees TA, Hariri M, Müller CT, Innmann MM, Spranz DM, Westhauser F, et al. Implantation Accuracy of Custom‐Made Acetabular Components With Iliac Stem Fixation for Large Bone Defects in Hip Revision Surgery. Orthopaedic Surgery. 2025. doi:10.1111/os.70186
BibTeX
@article{Nees2025,
author = {Nees, Timo A and Hariri, Mustafa and Müller, Christian T and Innmann, Moritz M and Spranz, David M and Westhauser, Fabian and Walker, Tilman and Reiner, Tobias},
title = {Implantation Accuracy of Custom‐Made Acetabular Components With Iliac Stem Fixation for Large Bone Defects in Hip Revision Surgery},
journal = {Orthopaedic Surgery},
year = {2025},
doi = {10.1111/os.70186}
}
EUVIMED