Vergleichsstudie in der Zeitschrift The Journal of Arthroplasty, 2025. Verfasst von Kevin C Ilo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Nottingham Elective Orthopaedic Services, Nottingham University Hospitals, Nottingham, United Kingdom. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Acetabulum, Surgical Mesh. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Trabecular metal is being increasingly used in primary total hip arthroplasty (THA). This study compared medium-term (< 15 years) outcomes of fiber mesh titanium and trabecular metal acetabular components. METHODS: This study included 6,563 patients who underwent primary THA with either fiber mesh titanium or trabecular metal-backed acetabular components. Data were sourced from a prospectively maintained local arthroplasty database and linked with the National Joint Registry. RESULTS: The 10-year survivorship was 97.3% for fiber mesh and 98.9% for porous tantalum groups (P = 0.009). Multivariate analysis showed no significant variable associated with reduced revision rates. CONCLUSIONS: Both fiber mesh titanium and trabecular metal acetabular components demonstrated high survivorship in THA, with trabecular metal showing statistically significant though marginally better survival. Despite the increased cost associated with trabecular metal, its use may be justified in complex primary and revision cases where increased primary stability may be required. Future research should focus on cost analysis and include patient-reported outcomes to guide implant selection further.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisAcetabulumSurgical MeshHumansMaleFemaleMiddle AgedAgedTitaniumProsthesis DesignAdultProsthesis FailureReoperationAged, 80 and overTantalumRetrospective StudiesTreatment Outcome

Stichwörter der Autor:innen

cementless fixationfiber meshprimary total hip arthroplastytrabecular metaluncemented acetabular component

Substanzen

TitaniumTantalum

Autor:innen und Institutionen

  • Nottingham Elective Orthopaedic Services, Nottingham University Hospitals, Nottingham, United Kingdom.
  • Nottingham Elective Orthopaedic Services, Nottingham University Hospitals, Nottingham, United Kingdom; Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, United Kingdom.
  • Nottingham Elective Orthopaedic Services, Nottingham University Hospitals, Nottingham, United Kingdom; University of Nottingham, Nottingham, United Kingdom.

Zitieren

APA

Ilo, K. C., Van Duren, B. H., Berber, R., Matar, H. E., Manktelow, A. R. J., & Bloch, B. V. (2025). Comparing Trabecular Metal Versus Fiber Mesh Cementless Acetabular Components: A Single-Center Study of 6,563 Hips. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2024.11.048

Vancouver

Ilo KC, Van Duren BH, Berber R, Matar HE, Manktelow ARJ, Bloch BV. Comparing Trabecular Metal Versus Fiber Mesh Cementless Acetabular Components: A Single-Center Study of 6,563 Hips. The Journal of Arthroplasty. 2025. doi:10.1016/j.arth.2024.11.048

BibTeX
@article{Ilo2025,
  author = {Ilo, Kevin C and Van Duren, Bernard H and Berber, Reshid and Matar, Hosam E and Manktelow, Andrew R J and Bloch, Benjamin V},
  title = {Comparing Trabecular Metal Versus Fiber Mesh Cementless Acetabular Components: A Single-Center Study of 6,563 Hips},
  journal = {The Journal of Arthroplasty},
  year = {2025},
  doi = {10.1016/j.arth.2024.11.048}
}
Kostenlos starten →