EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Arthroscopic Autologous Coracoacromial Ligament Augment Technique for Particle Thickness of Rotator Cuff with at Least Two Years Follow‐Up

Yuanhao Zhang, Min Zhou, Jingyi Hou, Jinming Zhang, Chuanhai Zhou iD, Yi Long iD, Meng Ke, Yiyong Tang, Rui Yang iD

Orthopaedic Surgery · 2023

DOI: 10.1111/os.13697 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthopaedic Surgery, 2023. Verfasst von Yuanhao Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China. Hauptthemen laut MEDLINE: Rotator Cuff Injuries, Acromioclavicular Joint. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Patch technology has been the new technique in the treatment of partial thickness of the rotator cuff tear (PTRCTs) to address the limitation of traditional techniques. Compared with allogeneic patches and artificial materials, coracoacromial ligament is obviously closer to their own biology. The purpose of the study was to evaluate the functional and radiographic outcomes following arthroscopic autologous coracoacromial ligament augment technique for treatment of PTRCTs.

Method

This study included three female patients with PTRCTs who underwent arthroscopy operation in 2017 with an average age of 51 years (range from 50 to 52 years). The coracoacromial ligament implant was attached to the bursal side surface of the tendon. The clinical results were evaluated by American Shoulder and Elbow Surgeons (ASES) score, Simple Shoulder Test (SST), acromiohumeral distance (AHD) and muscle strength before and 12 months after operation. Magnetic resonance imaging (MRI) was performed 24 months after operation to assess the integrity of the anatomical structure of the original tear site.

Result

The average ASES score improved significantly from 57.3 preoperatively to 95.0 at 1‐year follow‐up. The strength improved significantly from grade 3 preoperatively to grade 5 at 1 year. Two of three patients underwent the MRI at 2‐year follow‐up. Radiographic released the complete healing of rotator cuff tear. No implant‐related serious adverse events were reported.

Conclusion

The new technique of using autogenous coracoacromial ligament patch augment provides good clinical results on patients with PTRCTs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Rotator Cuff InjuriesAcromioclavicular JointHumansFemaleMiddle AgedRotator CuffFollow-Up StudiesTreatment OutcomeMagnetic Resonance ImagingArthroscopy

Stichwörter der Autor:innen

Arthroscopic Rotator Cuff RepairAutograftBiologic AugmentationCoracoacromial LigamentPartial Thickness of Rotator Cuff Tear

Autor:innen und Institutionen

  • Sun Yat-sen Memorial Hospital, Sun Yat-sen University, Guangzhou, China.

ORCID-Profile: Chuanhai Zhou, Yi Long, Rui Yang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, Y., Zhou, M., Hou, J., Zhang, J., Zhou, C., Long, Y., Ke, M., Tang, Y., & Yang, R. (2023). Arthroscopic Autologous Coracoacromial Ligament Augment Technique for Particle Thickness of Rotator Cuff with at Least Two Years Follow‐Up. Orthopaedic Surgery. https://doi.org/10.1111/os.13697

Vancouver

Zhang Y, Zhou M, Hou J, Zhang J, Zhou C, Long Y, et al. Arthroscopic Autologous Coracoacromial Ligament Augment Technique for Particle Thickness of Rotator Cuff with at Least Two Years Follow‐Up. Orthopaedic Surgery. 2023. doi:10.1111/os.13697

BibTeX
@article{Zhang2023,
  author = {Zhang, Yuanhao and Zhou, Min and Hou, Jingyi and Zhang, Jinming and Zhou, Chuanhai and Long, Yi and Ke, Meng and Tang, Yiyong and Yang, Rui},
  title = {Arthroscopic Autologous Coracoacromial Ligament Augment Technique for Particle Thickness of Rotator Cuff with at Least Two Years Follow‐Up},
  journal = {Orthopaedic Surgery},
  year = {2023},
  doi = {10.1111/os.13697}
}
Kostenlos starten →