The effectiveness of arthroscopically inserted onlay bioinductive implant on revision rotator cuff repair in workers’ compensation patients: a case-controlled cohort study with minimum 2-year follow-up
Journal of Shoulder and Elbow Surgery · 2025
DOI: 10.1016/j.jse.2025.11.021 ↗Kurz gefasst
Kohortenstudie in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025. Verfasst von Jamie Lau und 3 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic Research Institute, St George Hospital, University of New South Wales, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Rotator Cuff Injuries, Arthroscopy, Workers' Compensation, Rotator Cuff. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: Retear following rotator cuff repair is relatively common. Onlay biological grafts offer a potential solution, as a source of additional healing. The purpose of this study was to determine whether the addition of an onlay bioinductive implant would improve repair integrity and examiner-measured and/or patient-rated shoulder function at ≥2 years after revision arthroscopic rotator cuff repair in workers' compensation patients. We hypothesized that the addition of the onlay bioinductive implant in arthroscopic revision rotator cuff repairs would improve repair integrity and functional outcomes at minimum 2-year follow-up compared with standard repair. METHODS: A post hoc matched-cohort study was conducted on prospectively recruited workers' compensation patients who had revision rotator cuff repair with an onlay bioinductive implant (REGENETEN [Smith & Nephew]) (n = 16). The control group was workers' compensation patients who had revision rotator cuff repair without the bioinductive implant and was matched for age and tear size (n = 24). Kaplan-Meier curves were used to compare the primary outcome of repair integrity. RESULTS: No adverse effects with the bioinductive implant were identified. The retear rate in the bioinductive implant group was 50% (8/16) compared with 38% (9/24) in the control group at minimum 2-year follow-up (P = .522). There were no significant differences in patient-rated or examiner-measured outcomes between the groups at a median of 2.3-year follow-up. CONCLUSION: The addition of a biological patch to revision rotator cuff repair offered no advantage at 6-month follow-up. This study amplifies those findings and shows that revision rotator cuff repairs continue to fail from 6 months to ≥2 years, with the onlay bioinductive implant having no additional benefit to the longer-term health of the repair in this difficult population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopaedic Research Institute, St George Hospital, University of New South Wales, Sydney, New South Wales, Australia.
- Orthopaedic Research Institute, St George Hospital, University of New South Wales, Sydney, New South Wales, Australia. Electronic address: murrell.g@ori.org.au.
Zitieren
APA
Lau, J., Ting, R. S., Lam, P. H., & Murrell, G. A. C. (2025). The effectiveness of arthroscopically inserted onlay bioinductive implant on revision rotator cuff repair in workers’ compensation patients: a case-controlled cohort study with minimum 2-year follow-up. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2025.11.021
Vancouver
Lau J, Ting RS, Lam PH, Murrell GAC. The effectiveness of arthroscopically inserted onlay bioinductive implant on revision rotator cuff repair in workers’ compensation patients: a case-controlled cohort study with minimum 2-year follow-up. Journal of Shoulder and Elbow Surgery. 2025. doi:10.1016/j.jse.2025.11.021
BibTeX
@article{Lau2025,
author = {Lau, Jamie and Ting, Ryan S and Lam, Patrick H and Murrell, George A C},
title = {The effectiveness of arthroscopically inserted onlay bioinductive implant on revision rotator cuff repair in workers’ compensation patients: a case-controlled cohort study with minimum 2-year follow-up},
journal = {Journal of Shoulder and Elbow Surgery},
year = {2025},
doi = {10.1016/j.jse.2025.11.021}
}