EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Biomechanical Analysis of Lark‐Loop , Lasso‐Loop and Krackow Suture Technique in Tenodesis

Min Zhou iD, Chuanhai Zhou iD, Dedong Cui, Yi Long iD, Yan Yan, Zhenze Zheng, Ke Meng, Jinming Zhang, Jingyi Hou, Rui Yang iD

Orthopaedic Surgery · 2023

DOI: 10.1111/os.13669 ↗

At a glance

Journal article in Orthopaedic Surgery, 2023. Written by Min Zhou and 9 co-authors. Institution: Department of Orthopaedic Surgery, Sun Yat-Sen University 2nd Affiliated Hospital, Guangzhou, China. Major MEDLINE topics: Tenodesis. Cited 6 times so far (Crossref); 33 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objective

Strong tendon grasping is vital to the success of a tenodesis operation. The purpose of this study was to evaluate the initial tendon‐fixation strength of the Lark‐Loop technique in arthroscopic suprapectoral biceps tenodesis and compare it with others commonly used techniques.

Methods

Thirty‐three porcine superficial flexor digitorum tendons were harvested from a local slaughterhouse and randomly divided into three groups to perform three tendon fixation techniques (Lasso‐Loop stich group, Lark‐Loop stich group or Krackow stich group; 11 tendons each group) with a No. 2 suture, respectively. Each tendon was pre‐tensioned in 5°N for 2 min and then cyclically loaded 5 to 30°N for 500 cycles to assess displacement. After cyclic loading, the tendon was loaded to ultimate tendon‐suture configuration failure at the rate of 1 mm/s. Finally, the mode of failure and the construct stiffness of the tendon were recorded and calculated.

Results

After cyclical loading, the displacement of the Lark‐Loop group was equivalent to the Krakow group ( P > 0.9999) but significantly smaller than the Lasso‐Loop group ( P = 0.0009). The ultimate load to failure for the Lark‐Loop was equivalent to the Krakow technique group ( P = 0.1463) but significantly greater than the Lasso‐Loop group ( P < 0.0001). The stiffness for the Lark‐Loop was equivalent to the Krakow group ( P = 0.4718) but significantly greater than the Lasso‐Loop technique group ( P < 0.0001). In the Lark‐Loop and Krackow group, all the tendons failed by suture breakage, while all the tendons failed by suture cutting through the tendon in the Lasso‐Loop technique group.

Conclusion

Lark‐Loop suture technique has biomechanical properties comparable to Krackow and superior to the Lasso‐Loop in terms of suture displacement, ultimate load to failure, and stiffness. Therefore, the Lark‐Loop suture fixation technique may be beneficial for arthroscopic biceps tenodesis.

Subjects

MeSH terms (MEDLINE)

TenodesisAnimalsSwineSuture TechniquesTendonsMuscle, SkeletalSuturesBiomechanical PhenomenaCadaverSuture Anchors

Author keywords

ArthroscopicBiomechanicsKrackowLark-LoopLasso-LoopSuprapectoral tenodesis

Authors and institutions

  • Department of Orthopaedic Surgery, Sun Yat-Sen University 2nd Affiliated Hospital, Guangzhou, China.
  • Department of Orthopaedic Surgery, The Eighth Affiliated Hospital of Sun Yat-Sen University, Shenzhen, China.

ORCID profiles: Min Zhou, Chuanhai Zhou, Yi Long, Rui Yang

Cite

APA

Zhou, M., Zhou, C., Cui, D., Long, Y., Yan, Y., Zheng, Z., Meng, K., Zhang, J., Hou, J., & Yang, R. (2023). Biomechanical Analysis of Lark‐Loop , Lasso‐Loop and Krackow Suture Technique in Tenodesis. Orthopaedic Surgery. https://doi.org/10.1111/os.13669

Vancouver

Zhou M, Zhou C, Cui D, Long Y, Yan Y, Zheng Z, et al. Biomechanical Analysis of Lark‐Loop , Lasso‐Loop and Krackow Suture Technique in Tenodesis. Orthopaedic Surgery. 2023. doi:10.1111/os.13669

BibTeX
@article{Zhou2023,
  author = {Zhou, Min and Zhou, Chuanhai and Cui, Dedong and Long, Yi and Yan, Yan and Zheng, Zhenze and Meng, Ke and Zhang, Jinming and Hou, Jingyi and Yang, Rui},
  title = {Biomechanical Analysis of Lark‐Loop , Lasso‐Loop and Krackow Suture Technique in Tenodesis},
  journal = {Orthopaedic Surgery},
  year = {2023},
  doi = {10.1111/os.13669}
}
Start for free →