The tensile strength of different methods of anterior cruciate ligament graft end stitches in an animal model
The Knee · 2025
DOI: 10.1016/j.knee.2025.01.012 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Knee, 2025. Verfasst von Marcin Dembski und 5 weiteren Autor:innen. Beteiligte Einrichtung: St. Vincent de Paul Municipal Hospital, Wójta Radtkego 1 81-348 Gdynia, Poland. Hauptthemen laut MEDLINE: Tensile Strength, Suture Techniques, Anterior Cruciate Ligament Reconstruction, Tendons. Die Arbeit nennt 22 Literaturangaben. Gefördert von: National Science Centre Poland.
Abstract (Originalsprache)
BACKGROUND: There are several methods for stitching graft ends in anterior cruciate ligament reconstructive surgery. The tendon-suture construct should be able to withstand tensioning until the graft is stabilized with an implant. METHODS: In this biomechanical study, 40 porcine lower extremity tendons ends were stitched with No. 2 suture, secured to the grips of the Zwick-Roell testing machine and tested for load at failure and type of failure (tendon v/s suture thread). The applied force was linear, the results are given in Newtons (N) as a mean. The Mann-Whitney U test was used for statistical analysis. The following constructs were compared: a whipstitch of each tendon end individually with 3, 4, and 5 passes through the tendon, a whipstitch of both tendon ends folded together and a tendon end knot without stitching. RESULTS: All specimens survived the minimum tensile load of 80 N. The load at failure for whipstitch with 3,4 and 5 passes were 175 N, 211 N and 254 N respectively. The load at failure was greater for individual whipstitch than for both ends folded together (261 N v/s 152 N). The mean load at failure for braided graft was 209 N. The braided graft slips off the tendon before failure leading to uneven strength distribution during tensioning. CONCLUSION: Increasing number of suture passes resulted in higher load at failure. Individual tendon ends whipstitched with 5 passes was the strongest construct. All of the investigated techniques are sufficient to withstand the suggested optimal graft tension of 80 N.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- St. Vincent de Paul Municipal Hospital, Wójta Radtkego 1 81-348 Gdynia, Poland.
- Orthopedic Student Scientific Association, Medical University of Gdańsk, Nowe Ogrody 1-6 80-803 Gdańsk, Poland.
- University Clinical Centre, Dębinki 7 80-952 Gdańsk, Poland.
- Department of Orthopedic Surgery, Medical University of Gdańsk, Nowe Ogrody 1-6 80-803 Gdańsk, Poland. Electronic address: mceynowa@gumed.edu.pl.
- Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, Gabriela Narutowicza 11/12 80-233 Gdańsk, Poland.
Förderung
- National Science Centre Poland
Zitieren
APA
Dembski, M., Kawa, P., Tarnawski, J., Ceynowa, M., Żerdzicki, K., & Kłosowski, P. (2025). The tensile strength of different methods of anterior cruciate ligament graft end stitches in an animal model. The Knee. https://doi.org/10.1016/j.knee.2025.01.012
Vancouver
Dembski M, Kawa P, Tarnawski J, Ceynowa M, Żerdzicki K, Kłosowski P. The tensile strength of different methods of anterior cruciate ligament graft end stitches in an animal model. The Knee. 2025. doi:10.1016/j.knee.2025.01.012
BibTeX
@article{Dembski2025,
author = {Dembski, Marcin and Kawa, Patryk and Tarnawski, Jakub and Ceynowa, Marcin and Żerdzicki, Krzysztof and Kłosowski, Paweł},
title = {The tensile strength of different methods of anterior cruciate ligament graft end stitches in an animal model},
journal = {The Knee},
year = {2025},
doi = {10.1016/j.knee.2025.01.012}
}
EUVIMED