EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Repeatability of lipid layer thickness using LipiView® following removal of contact lenses and its relationship to comfort

Mukesh Kumar iD, Simin Masoudi, Ajay Kumar Vijay, Thomas John Naduvilath, Srikanth Dumpati, Ankit Raj, Mark Willcox

Ophthalmic and Physiological Optics · 2025

DOI: 10.1111/opo.13445 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Mukesh Kumar und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia. Hauptthemen laut MEDLINE: Tears, Contact Lenses, Hydrophilic, Interferometry, Dry Eye Syndromes. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods

A prospective study was conducted over two consecutive months, wherein CL wearers ( n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre‐corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h. Using the LipiView® interferometer, three measurements of the LLT (average, maximum and minimum) were recorded. Subjects' symptoms were evaluated with the Contact Lens Dry Eye Questionnaire‐8 (CLDEQ‐8) and correlations sought between post‐lens pre‐corneal tear film LLT and symptoms.

Results

The average, maximum and minimum intraclass correlation coefficients (ICC) of LLT measurements at baseline were 0.57, 0.39 and 0.66, respectively, indicating poor (ICC < 0.4) to moderate (≥0.4,

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TearsContact Lenses, HydrophilicInterferometryDry Eye SyndromesLipidsCorneaHumansProspective StudiesMaleFemaleAdultReproducibility of ResultsCross-Over StudiesYoung AdultMiddle Aged

Stichwörter der Autor:innen

CLDEQ‐8LipiViewcontact lensocular comfortrepeatability

Substanzen

Lipids

Autor:innen und Institutionen

  • School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.
  • Brien Holden Vision Institute, University of New South Wales, Sydney, New South Wales, Australia.
  • LV Prasad Eye Institute, Hyderabad, India.

ORCID-Profile: Mukesh Kumar

Zitieren

APA

Kumar, M., Masoudi, S., Vijay, A. K., Naduvilath, T. J., Dumpati, S., Raj, A., & Willcox, M. (2025). Repeatability of lipid layer thickness using LipiView® following removal of contact lenses and its relationship to comfort. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13445

Vancouver

Kumar M, Masoudi S, Vijay AK, Naduvilath TJ, Dumpati S, Raj A, et al. Repeatability of lipid layer thickness using LipiView® following removal of contact lenses and its relationship to comfort. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.13445