Reliability and agreement of subjective and objective non‐invasive break‐up time measurements in contact lens wearers
Ophthalmic and Physiological Optics · 2024
DOI: 10.1111/opo.13243 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2024. Verfasst von Laura Valencia-Nieto und 3 weiteren Autor:innen. Beteiligte Einrichtung: Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain. Hauptthemen laut MEDLINE: Dry Eye Syndromes, Contact Lenses, Hydrophilic. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministry of Universities and European Social Fund.
Abstract (Originalsprache)
Purpose
To assess the reliability and agreement of non‐invasive break‐up time (NIBUT) in symptomatic and asymptomatic contact lens (CL) wearers using automatic objective and conventional subjective techniques.
Methods
In this prospective cross‐sectional study, soft CL wearers, classified into symptomatic and asymptomatic based on the Contact Lens Dry Eye Questionnaire‐8, underwent NIBUT assessment with the CL in situ. The CA‐800 Corneal Analyzer and the EasyTear® VIEW+ Tearscope were used for objective and subjective evaluation, respectively. The within‐subject repeatability and intraclass correlation coefficient (ICC) were calculated. The agreement between the devices was compared using the Bland–Altman method.
Results
A total of 141 CL wearers (51 male and 90 female) with a mean age of 33.6 (SD = 12.2) years were included. The repeatability and ICC values obtained with the CA‐800 device when measuring NIBUT were 5.4 s and 58.6% across the whole sample, 4.2 s and 48.8% for the asymptomatic group and 7.1 s and 68.4% for the symptomatic group. When using the subjective method (EasyTear®), the respective repeatability and ICC values were 7.3 s and 32.7% for the whole sample, 6.5 s and 30.4% for the asymptomatic group and 8.6 s and 35.9% for the symptomatic group. The CA‐800 device provided significantly ( p < 0.001) shorter NIBUT values compared with EasyTear® for the whole sample (3.3 [2.9] vs. 8.1 [3.4] s), the asymptomatic (3.3 [3.0] vs. 7.7 [3.6] s) and the symptomatic (3.8 [2.9] vs. 8.6 [3.0] s) groups.
Conclusion
Objective (CA‐800) NIBUT assessment provides more reliable measurements than the conventional subjective technique using the EasyTear® device. However, CL practitioners should also be aware that the objective method indicates shorter NIBUT values. Symptomatic CL wearers may also need a higher number of NIBUT measurements to obtain reliable estimations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain.
- Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, Universidad de Valladolid, Valladolid, Spain.
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain.
- Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, Universidad de Valladolid, Valladolid, Spain.
ORCID-Profile: Alberto López-de la Rosa, María J González-García, Alberto López-Miguel
Förderung
- Ministry of Universities and European Social Fund
Zitieren
APA
Valencia-Nieto, L., López-de la Rosa, A., González-García, M. J., & López-Miguel, A. (2024). Reliability and agreement of subjective and objective non‐invasive break‐up time measurements in contact lens wearers. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13243
Vancouver
Valencia-Nieto L, López-de la Rosa A, González-García MJ, López-Miguel A. Reliability and agreement of subjective and objective non‐invasive break‐up time measurements in contact lens wearers. Ophthalmic and Physiological Optics. 2024. doi:10.1111/opo.13243
BibTeX
@article{ValenciaNieto2024,
author = {Valencia-Nieto, Laura and López-de la Rosa, Alberto and González-García, María J and López-Miguel, Alberto},
title = {Reliability and agreement of subjective and objective non‐invasive break‐up time measurements in contact lens wearers},
journal = {Ophthalmic and Physiological Optics},
year = {2024},
doi = {10.1111/opo.13243}
}
EUVIMED