EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The association between corneal immune cell dynamics and comfort in silicone hydrogel contact lens wearers

Laura Valencia-Nieto, Katie Edwards, Azadeh Tavakoli, María J González-García, Alberto López-Miguel, Samantha Dando, Alex Hui, Maria Markoulli, Eric B Papas, Luisa H Colorado

Contact Lens and Anterior Eye · 2025

DOI: 10.1016/j.clae.2025.102424 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Contact Lens and Anterior Eye, 2025. Verfasst von Laura Valencia-Nieto und 9 weiteren Autor:innen. Beteiligte Einrichtung: Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Facultad…. Hauptthemen laut MEDLINE: Tears, Cornea, Contact Lenses, Hydrophilic, Dry Eye Syndromes. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Valladolid, Government of Spain Ministry of Universities, Erasmus+.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To study the association between corneal immune cell dynamics and contact lens (CL) comfort, as well as tear film inflammatory mediators in established CL wearers. METHODS: A prospective, cross-sectional study including existing CL wearers was conducted. Symptoms were assessed with a comfort visual analog scale (VAS) and the Contact Lens Dry Eye Questionnaire-8. In-vivo corneal confocal microscopy was used to track immune cell dynamics over 3 timepoints at 5-minute intervals. Trajectory speed was calculated as the total length travelled by cells divided by time; displacement speed as the straight-line distance between the start and end positions of a cell divided by time; and persistence ratio as the ratio of displacement speed and trajectory speed. Measurements were performed for 1-3 cells per participant, and the minimum, maximum, and average values were analyzed. Tear film samples were collected to assess matrix metalloproteinase (MMP)-9, tissue inhibitor of metalloproteinase (TIMP)-1, and the MMP-9/TIMP-1 ratio. Correlations between immune cell dynamics, symptoms, and tear inflammatory mediators, were analyzed. RESULTS: Nineteen CL wearers (4 men and 15 women) aged 30 ± 5 years were included. Participants wore silicone hydrogel CLs for 8-10 h before clinical assessment. There was a significant association between comfort VAS and the maximum (rho = 0.533; p = 0.019) and average (rho = 0.506; p = 0.027) values of immune cell displacement speed. The concentration of MMP-9 was associated with the minimum value of trajectory speed (rho = 0.621; p = 0.031). Finally, the MMP-9/TIMP-1 ratio was associated with the maximum value of trajectory speed (rho = -0.717; p = 0.030), and the maximum (rho = -0.720; p = 0.008) and average (rho = -0.678; p = 0.015) values of displacement speed. CONCLUSION: Corneal immune cell dynamics is related to sensations of discomfort in silicone hydrogel CL wearers, with cell speed possibly being regulated by inflammatory mediators assessed from the tear film. These observations may aid in understanding the mechanisms underlying the discomfort response.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TearsCorneaContact Lenses, HydrophilicDry Eye SyndromesHumansMaleFemaleAdultCross-Sectional StudiesProspective StudiesMicroscopy, ConfocalSiliconesYoung AdultMatrix Metalloproteinase 9Tissue Inhibitor of Metalloproteinase-1Hydrogels

Stichwörter der Autor:innen

Contact lensCorneal immune cellDiscomfortTear film inflammatory mediator

Substanzen

SiliconesMatrix Metalloproteinase 9Tissue Inhibitor of Metalloproteinase-1Hydrogels

Autor:innen und Institutionen

  • Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, University of Valladolid, Valladolid, Spain.
  • Centre for Vision and Eye Research, Optometry and Vision Science, School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Brisbane, Australia.
  • School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
  • Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Facultad de Ciencias, University of Valladolid, Valladolid, Spain; Biomedical…
  • Instituto de Oftalmobiología Aplicada (IOBA), University of Valladolid, Valladolid, Spain; Departamento de Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia, Facultad de Medicina, University of Valladolid, Vall…
  • Centre for Immunology and Infection Control, School of Biomedical Sciences, Faculty of Health, Queensland University of Technology, Brisbane, Australia.

Förderung

  • University of Valladolid
  • Government of Spain Ministry of Universities
  • Erasmus+
  • European Social Fund Plus

Zitieren

APA

Valencia-Nieto, L., Edwards, K., Tavakoli, A., González-García, M. J., López-Miguel, A., Dando, S., Hui, A., Markoulli, M., Papas, E. B., & Colorado, L. H. (2025). The association between corneal immune cell dynamics and comfort in silicone hydrogel contact lens wearers. Contact Lens and Anterior Eye. https://doi.org/10.1016/j.clae.2025.102424

Vancouver

Valencia-Nieto L, Edwards K, Tavakoli A, González-García MJ, López-Miguel A, Dando S, et al. The association between corneal immune cell dynamics and comfort in silicone hydrogel contact lens wearers. Contact Lens and Anterior Eye. 2025. doi:10.1016/j.clae.2025.102424

BibTeX
@article{ValenciaNieto2025,
  author = {Valencia-Nieto, Laura and Edwards, Katie and Tavakoli, Azadeh and González-García, María J and López-Miguel, Alberto and Dando, Samantha and Hui, Alex and Markoulli, Maria and Papas, Eric B and Colorado, Luisa H},
  title = {The association between corneal immune cell dynamics and comfort in silicone hydrogel contact lens wearers},
  journal = {Contact Lens and Anterior Eye},
  year = {2025},
  doi = {10.1016/j.clae.2025.102424}
}
Kostenlos starten →