EUVIMEDSkopri EUVIMED
Open access · CC BY-NC-ND 4.0

Evaluation of the Volatile Sulfur Compound Stability in Breath Samples for Halitosis Remote Diagnosis

Eirini Militsi, Yves Reingewirtz, François Séverac, Olivier Huck iD, Pierre-Yves Gegout

Oral Diseases · 2026-10 · 32 (10) · 3356-3363

DOI: 10.1111/odi.70394 ↗

At a glance

Journal article in Oral Diseases, published online on 2026-06-22. Written by Eirini Militsi and 4 co-authors. Institution: Faculté de Chirurgie Dentaire, Université de Strasbourg, Strasbourg, France. Major MEDLINE topics: Halitosis, Sulfur Compounds. 40 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Hôpitaux Universitaire de Strasbourg.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

This study assessed the feasibility of remote halitosis diagnosis by evaluating VSC stability over 7 days and their association with periodontal parameters.

Methods

One hundred adult patients attending a periodontal examination were included. Oral gas samples were collected using plastic syringes and analyzed by gas chromatography (OralChroma) at baseline (D0) and after 7 days of storage at room temperature (D7). Hydrogen sulfide (H 2 S), methyl mercaptan (CH 3 SH), and dimethyl sulfide ((CH 3 ) 2 S) were quantified. Periodontal parameters were recorded. Correlations and agreement analyses were performed.

Results

At D0, 64% and 31% of patients were classified as having halitosis using thresholds of > 120 ppb and > 300 ppb, respectively. Mean VSC concentrations were 10.2 (33.1) ppb for H 2 S, 208.3 (443.2) ppb for CH 3 SH, and 79 (166) ppb for (CH 3 ) 2 S, and increased after 7 days of storage for all compounds except H 2 S. Only (CH 3 ) 2 S showed a significant correlation between D0 and D7 measurements. Agreement between halitosis diagnoses at D0 and D7 was poor for both thresholds (Cohen's kappa < 0.2). Associations between VSC levels and periodontal parameters were weak.

Conclusion

Delayed analysis of oral gas samples significantly altered VSC measurements limiting their reliability for remote halitosis diagnosis. Periodontal parameters were not strongly associated with VSC levels.

Subjects

MeSH terms (MEDLINE)

HalitosisSulfur CompoundsHumansBreath TestsFemaleAdultChromatography, GasMaleMiddle AgedHydrogen SulfideFeasibility StudiesSulfhydryl CompoundsSulfides

Author keywords

bad breathhalitosisperiodontitisremote analysisvolatile sulfur compounds

Substances

Sulfur Compoundsmethylmercaptandimethyl sulfideHydrogen SulfideSulfhydryl CompoundsSulfides

Authors and institutions

  • Faculté de Chirurgie Dentaire, Université de Strasbourg, Strasbourg, France.
  • Pôle de médecine et Chirurgie Bucco-Dentaires, Hôpitaux Universitaires de Strasbourg, Strasbourg, France.
  • Groupe Méthodes en Recherche Clinique (GMRC), Hôpitaux Universitaires de Strasbourg, Strasbourg, France.

ORCID profiles: Olivier Huck

Funding

  • Hôpitaux Universitaire de Strasbourg

Cite

APA

Militsi, E., Reingewirtz, Y., Séverac, F., Huck, O., & Gegout, P. Y. (2026). Evaluation of the Volatile Sulfur Compound Stability in Breath Samples for Halitosis Remote Diagnosis. Oral Diseases, 32(10), 3356-3363. https://doi.org/10.1111/odi.70394

Vancouver

Militsi E, Reingewirtz Y, Séverac F, Huck O, Gegout PY. Evaluation of the Volatile Sulfur Compound Stability in Breath Samples for Halitosis Remote Diagnosis. Oral Diseases. 2026;32(10):3356-3363. doi:10.1111/odi.70394

BibTeX
@article{Militsi2026,
  author = {Militsi, Eirini and Reingewirtz, Yves and Séverac, François and Huck, Olivier and Gegout, Pierre-Yves},
  title = {Evaluation of the Volatile Sulfur Compound Stability in Breath Samples for Halitosis Remote Diagnosis},
  journal = {Oral Diseases},
  year = {2026},
  volume = {32},
  number = {10},
  pages = {3356--3363},
  doi = {10.1111/odi.70394}
}
Start for free →