Evaluation of the Volatile Sulfur Compound Stability in Breath Samples for Halitosis Remote Diagnosis
Oral Diseases · 2026-10 · 32 (10) · 3356-3363
DOI: 10.1111/odi.70394 ↗At a glance
Journal article in Oral Diseases, published online on 2026-06-22. Written by Eirini Militsi and 4 co-authors. Institution: Faculté de Chirurgie Dentaire, Université de Strasbourg, Strasbourg, France. Major MEDLINE topics: Halitosis, Sulfur Compounds. 40 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Hôpitaux Universitaire de Strasbourg.
Abstract (original language)
Background
This study assessed the feasibility of remote halitosis diagnosis by evaluating VSC stability over 7 days and their association with periodontal parameters.
Methods
One hundred adult patients attending a periodontal examination were included. Oral gas samples were collected using plastic syringes and analyzed by gas chromatography (OralChroma) at baseline (D0) and after 7 days of storage at room temperature (D7). Hydrogen sulfide (H 2 S), methyl mercaptan (CH 3 SH), and dimethyl sulfide ((CH 3 ) 2 S) were quantified. Periodontal parameters were recorded. Correlations and agreement analyses were performed.
Results
At D0, 64% and 31% of patients were classified as having halitosis using thresholds of > 120 ppb and > 300 ppb, respectively. Mean VSC concentrations were 10.2 (33.1) ppb for H 2 S, 208.3 (443.2) ppb for CH 3 SH, and 79 (166) ppb for (CH 3 ) 2 S, and increased after 7 days of storage for all compounds except H 2 S. Only (CH 3 ) 2 S showed a significant correlation between D0 and D7 measurements. Agreement between halitosis diagnoses at D0 and D7 was poor for both thresholds (Cohen's kappa < 0.2). Associations between VSC levels and periodontal parameters were weak.
Conclusion
Delayed analysis of oral gas samples significantly altered VSC measurements limiting their reliability for remote halitosis diagnosis. Periodontal parameters were not strongly associated with VSC levels.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Faculté de Chirurgie Dentaire, Université de Strasbourg, Strasbourg, France.
- Pôle de médecine et Chirurgie Bucco-Dentaires, Hôpitaux Universitaires de Strasbourg, Strasbourg, France.
- Groupe Méthodes en Recherche Clinique (GMRC), Hôpitaux Universitaires de Strasbourg, Strasbourg, France.
ORCID profiles: Olivier Huck
Funding
- Hôpitaux Universitaire de Strasbourg
Cite
APA
Militsi, E., Reingewirtz, Y., Séverac, F., Huck, O., & Gegout, P. Y. (2026). Evaluation of the Volatile Sulfur Compound Stability in Breath Samples for Halitosis Remote Diagnosis. Oral Diseases, 32(10), 3356-3363. https://doi.org/10.1111/odi.70394
Vancouver
Militsi E, Reingewirtz Y, Séverac F, Huck O, Gegout PY. Evaluation of the Volatile Sulfur Compound Stability in Breath Samples for Halitosis Remote Diagnosis. Oral Diseases. 2026;32(10):3356-3363. doi:10.1111/odi.70394
BibTeX
@article{Militsi2026,
author = {Militsi, Eirini and Reingewirtz, Yves and Séverac, François and Huck, Olivier and Gegout, Pierre-Yves},
title = {Evaluation of the Volatile Sulfur Compound Stability in Breath Samples for Halitosis Remote Diagnosis},
journal = {Oral Diseases},
year = {2026},
volume = {32},
number = {10},
pages = {3356--3363},
doi = {10.1111/odi.70394}
}