Evaluation of thickness of 3D printed versus thermoformed aligners: A prospective in vivo ageing experiment
Orthodontics & Craniofacial Research · 2024
DOI: 10.1111/ocr.12822 ↗At a glance
Vergleichsstudie in Orthodontics & Craniofacial Research, 2024. Written by Babak Sayahpour and 7 co-authors. Institution: Department of Orthodontics, Johann-Wolfgang Goethe University, Frankfurt am Main, Germany. Major MEDLINE topics: Printing, Three-Dimensional. Cited 14 times so far (Crossref); 36 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Background
To compare and investigate the effects of intraoral ageing on the thickness of one group of directly printed and two groups of thermoformed aligners on the labial surface of maxillary central incisors. Materials and Methods Six groups (12 samples per group) were included in this prospective in vivo experiment. Groups DP‐Clin, INV‐Clin and CA‐Clin consisted of directly printed (Tera Harz TC‐85 DAC resin), thermoformed (Invisalign, PU based polymer) and in house thermoformed (CA‐Pro, PET‐G based polymer) aligners, retrieved after 1 week of intraoral service. Groups DP‐Ctr, INV‐Ctr and CA‐Ctr included unused aligners samples. Thickness measurements were conducted using confocal laser scanning microscopy (CLSM). Data that underwent log‐10 transformation was analysed by multiple linear regression analysis ( p < .05).
Results
Statistically significant differences were found between the materials in both Clin and Ctr categories ( p < .001). Group DP had the highest thickness among the groups and the least thickness was observed in the CA group ( p < .001). However, intraoral ageing did not significantly affect the aligner thickness of any groups.
Conclusions
Both thermoforming and direct printing of clear aligners led to thickness deviations in terms of increase for printed aligners and decrease for thermoformed aligners. Intraoral ageing did not affect the aligner thickness in any of the groups.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Orthodontics, Johann-Wolfgang Goethe University, Frankfurt am Main, Germany.
- Institute of Biostatistics and Mathematical Modelling, Faculty of Medicine, J. W. Goethe University Frankfurt, Frankfurt am Maine, Germany.
- Private Orthodontic Practice, Duesseldorf, Germany.
- Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania Luigi Vanvitelli, Naples, Italy.
ORCID profiles: Sara Eslami
Cite
APA
Sayahpour, B., Eslami, S., Stuhlfelder, J., Bühling, S., Dahmer, I., Goteni, M., Kopp, S., & Nucci, L. (2024). Evaluation of thickness of 3D printed versus thermoformed aligners: A prospective in vivo ageing experiment. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.12822
Vancouver
Sayahpour B, Eslami S, Stuhlfelder J, Bühling S, Dahmer I, Goteni M, et al. Evaluation of thickness of 3D printed versus thermoformed aligners: A prospective in vivo ageing experiment. Orthodontics & Craniofacial Research. 2024. doi:10.1111/ocr.12822
BibTeX
@article{Sayahpour2024,
author = {Sayahpour, Babak and Eslami, Sara and Stuhlfelder, Jakob and Bühling, Sarah and Dahmer, Iulia and Goteni, Malcolm and Kopp, Stefan and Nucci, Ludovica},
title = {Evaluation of thickness of 3D printed versus thermoformed aligners: A prospective in vivo ageing experiment},
journal = {Orthodontics & Craniofacial Research},
year = {2024},
doi = {10.1111/ocr.12822}
}
EUVIMED