A finite element analysis of stress distribution with various directions of intermaxillary fixation using orthodontic mini‐implants and elastics following mandibular advancement with a bilateral sagittal split ramus osteotomy

Mi-Young Lee, Jae Hyun Park iD, Sung-Jin Park, Na-Young Chang, Jong-Moon Chae iD

Orthodontics & Craniofacial Research · 2024

DOI: 10.1111/ocr.12698 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthodontics & Craniofacial Research, 2024. Verfasst von Mi-Young Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Seoul National University Gwan-ak Dental Hospital, Seoul, South Korea. Hauptthemen laut MEDLINE: Dental Implants, Mandibular Advancement, Orthodontic Anchorage Procedures. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This finite element analysis (FEA) aimed to assess the stress distribution in the mandible and fixation system with various directions of the intermaxillary fixation (IMF) using mini‐implants (MIs) and elastics following mandibular advancement with a bilateral sagittal split ramus osteotomy (BSSRO). Materials and Methods A total of nine mandibular advancement models were set according to the position of the MIs (1.6 mm in diameter, 8 mm in length) and direction of the IMF elastics (1/4 inch, 5 oz). Major and minor principal stresses in the cortical and cancellous bones, von Mises stresses in the fixation system (miniplate and monocortical screws), and bending angles of the miniplate were analysed.

Results

Compressive and tensile stress distributions in the mandible and von Mises stress distributions in the fixation system were greater in models with a Class III IMF elastic direction and a higher IMF elastic force than in models with a Class II IMF elastic direction and a lower IMF elastic force. The bending angle of the miniplate was negligible.

Conclusions

Stress distributions in the bone and fixation system varied depending on the direction, amount of force, and position of IMF elastics and MIs. Conclusively, IMF elastics in the Class II direction with minimal load in the area close to the osteotomy site should be recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsMandibular AdvancementOrthodontic Anchorage ProceduresOsteotomy, Sagittal Split RamusFinite Element AnalysisBone PlatesBone ScrewsStress, MechanicalMandible

Stichwörter der Autor:innen

bilateral sagittal split ramus osteotomyfinite element analysisfixation miniplateintermaxillary fixationorthodontic mini-implant and elastics

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Orthodontics, Seoul National University Gwan-ak Dental Hospital, Seoul, South Korea.
  • Postgraduate Orthodontic Program, Arizona School of Dentistry and Oral Health, A.T. Still University, Mesa, Arizona, USA.
  • Graduate School of Dentistry, Kyung Hee University, Seoul, South Korea.
  • Department of Oral and Maxillofacial Surgery, GangNam CHA Hospital, CHA University School of Medicine, Seoul, South Korea.
  • Department of Orthodontics, School of Dentistry, University of Wonkwang, Wonkwang Dental Research Institute, Iksan, South Korea.

ORCID-Profile: Jae Hyun Park, Jong-Moon Chae

Zitieren

APA

Lee, M. Y., Park, J. H., Park, S. J., Chang, N. Y., & Chae, J. M. (2024). A finite element analysis of stress distribution with various directions of intermaxillary fixation using orthodontic mini‐implants and elastics following mandibular advancement with a bilateral sagittal split ramus osteotomy. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.12698

Vancouver

Lee MY, Park JH, Park SJ, Chang NY, Chae JM. A finite element analysis of stress distribution with various directions of intermaxillary fixation using orthodontic mini‐implants and elastics following mandibular advancement with a bilateral sagittal split ramus osteotomy. Orthodontics & Craniofacial Research. 2024. doi:10.1111/ocr.12698

BibTeX
@article{Lee2024,
  author = {Lee, Mi-Young and Park, Jae Hyun and Park, Sung-Jin and Chang, Na-Young and Chae, Jong-Moon},
  title = {A finite element analysis of stress distribution with various directions of intermaxillary fixation using orthodontic mini‐implants and elastics following mandibular advancement with a bilateral sagittal split ramus osteotomy},
  journal = {Orthodontics & Craniofacial Research},
  year = {2024},
  doi = {10.1111/ocr.12698}
}
Kostenlos starten →