Evaluation of two stable internal fixation techniques in mandibular ramus sagittal osteotomy: a three-dimensional finite element study
Oral and Maxillofacial Surgery · 2025
DOI: 10.1007/s10006-025-01357-z ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Oral and Maxillofacial Surgery, 2025. Verfasst von Kaline de Moura Silva und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, Federal University of Amazonas, Manaus, Amazonas, Brazil. kalinectbmf@gmail.com. Hauptthemen laut MEDLINE: Finite Element Analysis, Osteotomy, Sagittal Split Ramus, Imaging, Three-Dimensional, Mandible. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate and compare, using finite elements three-dimensional (3D) analysis, two techniques of stable internal fixation in 2 patterns of sagittal split ramus osteotomy (SSRO) and the repercussions of occlusal load distribution in the postoperative period. METHODS: A 3D finite element model of a hemimandible was created. The models were divided into 2 split patterns of SSRO advanced 5 mm forward, a split pattern (1) following the Epker osteotomy design and another split pattern (2) following Posnick osteotomy design, simulated by CAD (Computer Aided Engineering) Rhinoceros 3D®. Two internal fixation techniques were simulated by HyperMesh: A- one titanium miniplate of the Arnett system (1 mm) for orthognathic surgery fixed with four monocortical screws; B- one titanium plate fixed with four monocortical screws and one bicortical screw. Resistance, stress and displacement were analyzed applying a 200 N vertical load to the occlusal surface region of the mandibular first molar and a 100 N to the incisal surface of the mandibular central incisor. RESULTS: The results were presented through the von Mises stress analysis. A difference in the displacement of the models fixed with only one miniplate and four monocortical screws was observed. The models with split pattern (2) presented smaller displacements when compared to the split pattern (1). For metallic components, the split pattern (2) exhibits lower strain values, although it has no significant difference. CONCLUSION: The fixation technique B proved to be more rigid and lower stress values both in the bone and in the plate, as well as lower deformation and displacements were shown in comparison to fixation technique A for all mandibular movements and forces.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Surgery, Federal University of Amazonas, Manaus, Amazonas, Brazil. kalinectbmf@gmail.com.
- Department of Mechanical Engineering, University of Campinas, Campinas, São Paulo, Brazil.
- Department of Oral and Maxillofacial Surgery, São Paulo State University, Araraquara, São Paulo, Brazil.
- Department of Oral and Maxillofacial Surgery, Federal University of Amazonas, Manaus, Amazonas, Brazil.
Zitieren
APA
Silva, K. M., Machado, L. M. R., Leite, M. G. M., Noritomi, P. Y., de Jesus, G. P., & de Moura, A. L. (2025). Evaluation of two stable internal fixation techniques in mandibular ramus sagittal osteotomy: a three-dimensional finite element study. Oral and Maxillofacial Surgery. https://doi.org/10.1007/s10006-025-01357-z
Vancouver
Silva KM, Machado LMR, Leite MGM, Noritomi PY, de Jesus GP, de Moura AL. Evaluation of two stable internal fixation techniques in mandibular ramus sagittal osteotomy: a three-dimensional finite element study. Oral and Maxillofacial Surgery. 2025. doi:10.1007/s10006-025-01357-z
BibTeX
@article{Silva2025,
author = {Silva, Kaline de Moura and Machado, Leonardo Mendes Ribeiro and Leite, Milena Gomes Melo and Noritomi, Pedro Yoshito and de Jesus, Giorge Pessoa and de Moura, Andrezza Lauria},
title = {Evaluation of two stable internal fixation techniques in mandibular ramus sagittal osteotomy: a three-dimensional finite element study},
journal = {Oral and Maxillofacial Surgery},
year = {2025},
doi = {10.1007/s10006-025-01357-z}
}