EUVIMEDEUVIMED entdecken
Crossref

Evaluation of effects of brackets and orthodontic wires on intraoral scans: A prospective in‐vivo study

Mario Palone iD, Marco Bellavia, Matteo Floris, Andrea Rombolà, Francesca Cremonini, Paolo Albertini iD, Luca Lombardo

Orthodontics & Craniofacial Research · 2024

DOI: 10.1111/ocr.12682 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Orthodontics & Craniofacial Research, 2024. Verfasst von Mario Palone und 6 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate School of Orthodontics, University of Ferrara, Ferrara, Italy. Hauptthemen laut MEDLINE: Orthodontic Wires, Orthodontic Brackets. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate any distortion produced by multibracket fixed orthodontic appliances on digital models obtained from intraoral scans (IOS), considering the presence of both brackets only and brackets/archwire combination. Setting/Sample The IOS data of the arches of 20 patients (12 females and 8 males; mean age = 15.55 ± 2.84 years) were acquired using the CS3600 intraoral scanner (Carestream Dental, Atlanta, USA), without any appliances (model A), with vestibular brackets alone (model B) and then with brackets and orthodontic archwire fitted (model C). Materials and Methods Data were acquired between the months of January and October 2021 at the moment of indirect bonding phase. On each model, five intra‐arch linear measurements were obtained (inter‐canine, inter‐premolar 1 and 2, inter‐molar and arch depth), and after digital matching between model A and B (match 1) and A and C (match 2), the linear discrepancies were evaluated at 20 points (10 occlusal and 10 gingivolingual) previous identified on the reference model A. All measurements were performed using Geomagic Control X software (3D Systems, Morrisville, USA), and any dimensional variations and distortions were evaluated by the linear regression analysis and two‐sample t ‐test ( P ≤ .05).

Results

The results show an almost perfect correlation between both models B and C and the reference model A, both as regards the intra‐arch linear measurements and the linear discrepancies found at the 20 identified points.

Conclusions

Multibracket fixed orthodontic appliances do not produce any relevant distortions in digital models obtained via intraoral scanning. Therefore, the removal of archwire is not mandatory before IOS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthodontic WiresOrthodontic BracketsMaleFemaleHumansChildAdolescentProspective StudiesOrthodontic AppliancesSoftwareImaging, Three-Dimensional

Stichwörter der Autor:innen

accuracyimage distortionintraoral scannerintraoral scanningorthodontic archwireorthodontic brackets

Autor:innen und Institutionen

  • Postgraduate School of Orthodontics, University of Ferrara, Ferrara, Italy.
  • Department of Biomedical Sciences, University of Sassari, Sassari, Italy.

ORCID-Profile: Mario Palone, Paolo Albertini

Zitieren

APA

Palone, M., Bellavia, M., Floris, M., Rombolà, A., Cremonini, F., Albertini, P., & Lombardo, L. (2024). Evaluation of effects of brackets and orthodontic wires on intraoral scans: A prospective in‐vivo study. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.12682

Vancouver

Palone M, Bellavia M, Floris M, Rombolà A, Cremonini F, Albertini P, et al. Evaluation of effects of brackets and orthodontic wires on intraoral scans: A prospective in‐vivo study. Orthodontics & Craniofacial Research. 2024. doi:10.1111/ocr.12682

BibTeX
@article{Palone2024,
  author = {Palone, Mario and Bellavia, Marco and Floris, Matteo and Rombolà, Andrea and Cremonini, Francesca and Albertini, Paolo and Lombardo, Luca},
  title = {Evaluation of effects of brackets and orthodontic wires on intraoral scans: A prospective in‐vivo study},
  journal = {Orthodontics & Craniofacial Research},
  year = {2024},
  doi = {10.1111/ocr.12682}
}
Kostenlos starten →