Evaluation of effects of brackets and orthodontic wires on intraoral scans: A prospective in‐vivo study
Orthodontics & Craniofacial Research · 2024
DOI: 10.1111/ocr.12682 ↗At a glance
Journal article in Orthodontics & Craniofacial Research, 2024. Written by Mario Palone and 6 co-authors. Institution: Postgraduate School of Orthodontics, University of Ferrara, Ferrara, Italy. Major MEDLINE topics: Orthodontic Wires, Orthodontic Brackets. Cited 6 times so far (Crossref); 35 references.
Abstract (original language)
Objective
To evaluate any distortion produced by multibracket fixed orthodontic appliances on digital models obtained from intraoral scans (IOS), considering the presence of both brackets only and brackets/archwire combination. Setting/Sample The IOS data of the arches of 20 patients (12 females and 8 males; mean age = 15.55 ± 2.84 years) were acquired using the CS3600 intraoral scanner (Carestream Dental, Atlanta, USA), without any appliances (model A), with vestibular brackets alone (model B) and then with brackets and orthodontic archwire fitted (model C). Materials and Methods Data were acquired between the months of January and October 2021 at the moment of indirect bonding phase. On each model, five intra‐arch linear measurements were obtained (inter‐canine, inter‐premolar 1 and 2, inter‐molar and arch depth), and after digital matching between model A and B (match 1) and A and C (match 2), the linear discrepancies were evaluated at 20 points (10 occlusal and 10 gingivolingual) previous identified on the reference model A. All measurements were performed using Geomagic Control X software (3D Systems, Morrisville, USA), and any dimensional variations and distortions were evaluated by the linear regression analysis and two‐sample t ‐test ( P ≤ .05).
Results
The results show an almost perfect correlation between both models B and C and the reference model A, both as regards the intra‐arch linear measurements and the linear discrepancies found at the 20 identified points.
Conclusions
Multibracket fixed orthodontic appliances do not produce any relevant distortions in digital models obtained via intraoral scanning. Therefore, the removal of archwire is not mandatory before IOS.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Postgraduate School of Orthodontics, University of Ferrara, Ferrara, Italy.
- Department of Biomedical Sciences, University of Sassari, Sassari, Italy.
ORCID profiles: Mario Palone, Paolo Albertini
Cite
APA
Palone, M., Bellavia, M., Floris, M., Rombolà, A., Cremonini, F., Albertini, P., & Lombardo, L. (2024). Evaluation of effects of brackets and orthodontic wires on intraoral scans: A prospective in‐vivo study. Orthodontics & Craniofacial Research. https://doi.org/10.1111/ocr.12682
Vancouver
Palone M, Bellavia M, Floris M, Rombolà A, Cremonini F, Albertini P, et al. Evaluation of effects of brackets and orthodontic wires on intraoral scans: A prospective in‐vivo study. Orthodontics & Craniofacial Research. 2024. doi:10.1111/ocr.12682
BibTeX
@article{Palone2024,
author = {Palone, Mario and Bellavia, Marco and Floris, Matteo and Rombolà, Andrea and Cremonini, Francesca and Albertini, Paolo and Lombardo, Luca},
title = {Evaluation of effects of brackets and orthodontic wires on intraoral scans: A prospective in‐vivo study},
journal = {Orthodontics & Craniofacial Research},
year = {2024},
doi = {10.1111/ocr.12682}
}
EUVIMED