Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study
Neurogastroenterology & Motility · 2025-12 · 37 (12)
DOI: 10.1111/nmo.70090 ↗At a glance
Journal article in Neurogastroenterology & Motility, published online on 2025-06-02. Written by Alberto Ezquerra-Durán and 6 co-authors. Institution: Neurogastroenterology and Motility Unit, Gastroenterology Department, Hospital Clinic of Barcelona, Barcelona, Spain. Major MEDLINE topics: Anal Canal, Manometry, Imaging, Three-Dimensional, Fecal Incontinence. Cited 2 times so far (Crossref); 36 references. Funded by: Instituto de Salud Carlos III, European Union, European Commission.
Abstract (original language)
Background
Obstetric anal sphincter injuries (OASIs) occur during childbirth, affecting up to 11.0% of women. Three‐Dimensional High‐Resolution Anorectal Manometry (3D‐HR‐ARM) provides an advanced evaluation of pathophysiological anorectal abnormalities and allows identification of potential lesions. The aim of the study was to evaluate the diagnostic accuracy and inter‐rater reliability of (3D‐HR‐ARM) in identifying OASIs compared to ultrasound assessment.
Methods
A retrospective cohort study was conducted at a tertiary referral center from January 2021 to June 2023. Women with anal incontinence (AI) following a vaginal delivery underwent assessment with both 3D‐HR‐ARM and endoanal ultrasound (3D‐EAUS). Diagnostic accuracy in identifying anal sphincter defects was determined using 3D‐EAUS as the gold standard, and inter‐rater reliability was assessed among multiple observers. Key Results Among 35 women, 19 had OASIs. For identifying severe residual defects (global Starck score ≥ 8), 3D‐HR‐ARM demonstrated an accuracy of 95.7% (95% CI 79.0–99.2), sensitivity of 100% (95% CI 64.6–100), specificity of 93.8% (95% CI 71.7–98.9), positive predictive value (PPV) of 87.5% (95% CI 52.9–97.8), and negative predictive value of 100% (95% CI 79.6–100). However, its accuracy decreased to 68.6% (95% CI 52.0–81.4) for detecting any sphincter defect. Inter‐rater agreement varied from good ( κ = 0.60) to mild ( κ = 0.27), depending on the observer pair.
Conclusions
3D‐HR‐ARM shows potential for the identification of severe OASIs in women with AI symptoms. However, its moderate accuracy for mild defects and significant inter‐rater variability underscore the need for standardized protocols and additional training to improve reliability.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Neurogastroenterology and Motility Unit, Gastroenterology Department, Hospital Clinic of Barcelona, Barcelona, Spain.
- Pelvic Floor Unit, ICGON, Hospital Clinic of Barcelona, University of Barcelona, Barcelona, Spain.
- Digestive Physiology and Motility Lab, Veracruzana University, Xalapa, Mexico.
- Integral Center for Gastroenterology and Advanced Motility (CIGMA), Veracruz, Mexico.
ORCID profiles: Alberto Ezquerra-Durán, José María Remes-Troche, Isis K Araujo, Elizabeth Barba
Funding
- Instituto de Salud Carlos III
- European Union
- European Commission
Cite
APA
Ezquerra-Durán, A., Ros, C., Remes-Troche, J. M., García-Zermeño, K. R., Luzko, I., Araujo, I. K., & Barba, E. (2025). Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study. Neurogastroenterology & Motility, 37(12). https://doi.org/10.1111/nmo.70090
Vancouver
Ezquerra-Durán A, Ros C, Remes-Troche JM, García-Zermeño KR, Luzko I, Araujo IK, et al. Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study. Neurogastroenterology & Motility. 2025;37(12). doi:10.1111/nmo.70090
BibTeX
@article{EzquerraDurn2025,
author = {Ezquerra-Durán, Alberto and Ros, Cristina and Remes-Troche, José María and García-Zermeño, Karla Rocío and Luzko, Irina and Araujo, Isis K and Barba, Elizabeth},
title = {Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study},
journal = {Neurogastroenterology & Motility},
year = {2025},
volume = {37},
number = {12},
doi = {10.1111/nmo.70090}
}
EUVIMED