Feasibility of IAPWG protocol in performing high-definition three-dimensional anorectal manometry: A prospective, multicentric italian study
Techniques in Coloproctology · 2024
DOI: 10.1007/s10151-024-03028-9 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Techniques in Coloproctology, 2024. Verfasst von D Della Casa und 7 weiteren Autor:innen. Beteiligte Einrichtung: UOC Endoscopia Digestiva Interventistica, ASST Spedali Civili, Brescia, Italy. dellacasanico@virgilio.it. Hauptthemen laut MEDLINE: Manometry, Feasibility Studies, Anal Canal, Rectum. Die Arbeit nennt 14 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The International Anorectal Physiology Working Group (IAPWG) suggests a standardized protocol to perform high-resolution anorectal manometry. The applicability and possible limitations of the IAPWG protocol in performing three-dimensional high-definition anorectal manometry (3D-ARM) have still to be extensively evaluated. METHODS: The IAPWG protocol was applied in performing 3D-ARM. Anorectal manometry (ARM) and a balloon expulsion test (BET) were performed according to IAPGW protocol in 290 patients. KEY RESULTS: A total of 84 males and 206 females (mean age 57.1 ± 15.7 years) were enrolled in six Italian centers. The reasons for which the patients were sent to perform 3D-ARM were: constipation (53.1%), fecal incontinence (26.9%), anal pain (3.1%), postsurgical (3.8%) and presurgical evaluation (4.8%), prolapse (3.4%), anal fissure (2.8%), and other (2.1%). Due to organic and functional conditions (low rectal anterior resections, rectal prolapses, and J-pouch after colectomy), we were unable to perform a complete 3D-ARM on six patients. Overall, a complete 3D-ARM and BET following IAPWG protocol was carried out in 284 patients (97.9%). The following were recorded: rest pressure (81.9 ± 32.0 mmHg) and length of the anal sphincter (37.0 ± 6.2 cm), maximum anal squeeze pressure (201.6 ± 81.3 mmHg), squeeze duration (22.0 ± 8.8 s), maximum rectal (48.7 ± 41.0 mmHg) and minimum anal pressure (73.3 ± 36.5 mmHg) during push, presence/absence of a dyssynergic pattern, cough reflex and rectal sensations (first constant sensation 48.4 ± 29.5 mL, desire to defecate 83.7 ± 52.1 mL, and maximum tolerated volume 149.5 ± 72.6 mL), and presence/absence of rectoanal inhibitory reflex. Mean 3D-ARM registration time was 14 min 7 s ± 3 min 12 s. CONCLUSIONS: This is the first multicentric study that evaluates the applicability of the IAPWG protocol in 3D-ARM performed in different manometric laboratories (both gastroenterological and surgical). The IAPWG protocol was easy to perform and was not time consuming. A diagnosis according to the London Classification was easily obtained in most patients in which 3D-ARM was carried out. No clear limitations to the applicability of the IAPWG protocol were detected.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- UOC Endoscopia Digestiva Interventistica, ASST Spedali Civili, Brescia, Italy. dellacasanico@virgilio.it.
- Gastrointestinal Unit, Department of Translational Sciences and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy.
- SC Chirurgia Generale Oncologica e Mininvasiva. Ospedale Niguarda, Milan, Italy.
- Colorectal Surgery, Fondazione IRCCS Istituto Nazionale dei Tumori, Milan, Italy.
- Gastroenterology and Endoscopy Unit, AULSS 8 Ospedale San Bortolo, Vicenza, Italy.
- UOC Gastroenterologia ed Endoscopia Digestiva, ASST Fatebenefratelli Sacco, Dipartimento di Scienze Biomediche e Cliniche 'L. Sacco', Università Degli Studi di Milano, Milan, Italy.
ORCID-Profile: D Della Casa
Zitieren
APA
Della Casa, D., Lambiase, C., Origi, M., Battaglia, L., Guaglio, M., Cataudella, G., Dell'Era, A., & Bellini, M. (2024). Feasibility of IAPWG protocol in performing high-definition three-dimensional anorectal manometry: A prospective, multicentric italian study. Techniques in Coloproctology. https://doi.org/10.1007/s10151-024-03028-9
Vancouver
Della Casa D, Lambiase C, Origi M, Battaglia L, Guaglio M, Cataudella G, et al. Feasibility of IAPWG protocol in performing high-definition three-dimensional anorectal manometry: A prospective, multicentric italian study. Techniques in Coloproctology. 2024. doi:10.1007/s10151-024-03028-9
BibTeX
@article{DellaCasa2024,
author = {Della Casa, D and Lambiase, C and Origi, M and Battaglia, L and Guaglio, M and Cataudella, G and Dell'Era, A and Bellini, M},
title = {Feasibility of IAPWG protocol in performing high-definition three-dimensional anorectal manometry: A prospective, multicentric italian study},
journal = {Techniques in Coloproctology},
year = {2024},
doi = {10.1007/s10151-024-03028-9}
}
EUVIMED