EUVIMEDEUVIMED entdecken
Crossref

Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study

Alberto Ezquerra-Durán iD, Cristina Ros, José María Remes-Troche iD, Karla Rocío García-Zermeño, Irina Luzko, Isis K Araujo iD, Elizabeth Barba iD

Neurogastroenterology & Motility · 2025-12 · 37 (12)

DOI: 10.1111/nmo.70090 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neurogastroenterology & Motility, online erschienen am 02.06.2025. Verfasst von Alberto Ezquerra-Durán und 6 weiteren Autor:innen. Beteiligte Einrichtung: Neurogastroenterology and Motility Unit, Gastroenterology Department, Hospital Clinic of Barcelona, Barcelona, Spain. Hauptthemen laut MEDLINE: Anal Canal, Manometry, Imaging, Three-Dimensional, Fecal Incontinence. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Instituto de Salud Carlos III, European Union, European Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Obstetric anal sphincter injuries (OASIs) occur during childbirth, affecting up to 11.0% of women. Three‐Dimensional High‐Resolution Anorectal Manometry (3D‐HR‐ARM) provides an advanced evaluation of pathophysiological anorectal abnormalities and allows identification of potential lesions. The aim of the study was to evaluate the diagnostic accuracy and inter‐rater reliability of (3D‐HR‐ARM) in identifying OASIs compared to ultrasound assessment.

Methods

A retrospective cohort study was conducted at a tertiary referral center from January 2021 to June 2023. Women with anal incontinence (AI) following a vaginal delivery underwent assessment with both 3D‐HR‐ARM and endoanal ultrasound (3D‐EAUS). Diagnostic accuracy in identifying anal sphincter defects was determined using 3D‐EAUS as the gold standard, and inter‐rater reliability was assessed among multiple observers. Key Results Among 35 women, 19 had OASIs. For identifying severe residual defects (global Starck score ≥ 8), 3D‐HR‐ARM demonstrated an accuracy of 95.7% (95% CI 79.0–99.2), sensitivity of 100% (95% CI 64.6–100), specificity of 93.8% (95% CI 71.7–98.9), positive predictive value (PPV) of 87.5% (95% CI 52.9–97.8), and negative predictive value of 100% (95% CI 79.6–100). However, its accuracy decreased to 68.6% (95% CI 52.0–81.4) for detecting any sphincter defect. Inter‐rater agreement varied from good ( κ = 0.60) to mild ( κ = 0.27), depending on the observer pair.

Conclusions

3D‐HR‐ARM shows potential for the identification of severe OASIs in women with AI symptoms. However, its moderate accuracy for mild defects and significant inter‐rater variability underscore the need for standardized protocols and additional training to improve reliability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anal CanalManometryImaging, Three-DimensionalFecal IncontinenceDelivery, ObstetricObstetric Labor ComplicationsHumansFemaleAdultRetrospective StudiesReproducibility of ResultsFeasibility StudiesPregnancyObserver Variation

Stichwörter der Autor:innen

3D high resolution anorectal manometryendoanal ultrasoundfecal incontinenceobstetric anal sphincter injuries

Autor:innen und Institutionen

  • Neurogastroenterology and Motility Unit, Gastroenterology Department, Hospital Clinic of Barcelona, Barcelona, Spain.
  • Pelvic Floor Unit, ICGON, Hospital Clinic of Barcelona, University of Barcelona, Barcelona, Spain.
  • Digestive Physiology and Motility Lab, Veracruzana University, Xalapa, Mexico.
  • Integral Center for Gastroenterology and Advanced Motility (CIGMA), Veracruz, Mexico.

ORCID-Profile: Alberto Ezquerra-Durán, José María Remes-Troche, Isis K Araujo, Elizabeth Barba

Förderung

  • Instituto de Salud Carlos III
  • European Union
  • European Commission

Zitieren

APA

Ezquerra-Durán, A., Ros, C., Remes-Troche, J. M., García-Zermeño, K. R., Luzko, I., Araujo, I. K., & Barba, E. (2025). Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study. Neurogastroenterology & Motility, 37(12). https://doi.org/10.1111/nmo.70090

Vancouver

Ezquerra-Durán A, Ros C, Remes-Troche JM, García-Zermeño KR, Luzko I, Araujo IK, et al. Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study. Neurogastroenterology & Motility. 2025;37(12). doi:10.1111/nmo.70090

BibTeX
@article{EzquerraDurn2025,
  author = {Ezquerra-Durán, Alberto and Ros, Cristina and Remes-Troche, José María and García-Zermeño, Karla Rocío and Luzko, Irina and Araujo, Isis K and Barba, Elizabeth},
  title = {Diagnostic Accuracy and Inter‐Rater Reliability of Three‐Dimensional High Resolution Anorectal Manometry (3D‐HR‐ARM) in the Diagnosis of Obstetric Anal Sphincter Injuries (OASIs): A Feasibility Study},
  journal = {Neurogastroenterology & Motility},
  year = {2025},
  volume = {37},
  number = {12},
  doi = {10.1111/nmo.70090}
}
Kostenlos starten →