Validation of Plateletworks ADP for the ProCyte Dx analyzer
Journal of Veterinary Internal Medicine · 2023
DOI: 10.1111/jvim.16670 ↗At a glance
Journal article in Journal of Veterinary Internal Medicine, 2023. Written by Matthew R Kornya and 3 co-authors. Institution: Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada. Major MEDLINE topics: Platelet Function Tests, Platelet Aggregation. Cited 2 times so far (Crossref); 33 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Ontario Veterinary College Pet Trust, OVC Pet Trust.
Abstract (original language)
Background
Platelet function testing in cats allows determination of clopidogrel effect. Plateletworks assesses aggregation based on decreasing platelet counts on hematology analyzers in response to agonists. It has not been validated for the IDEXX ProCyte Dx analyzer. Ideal time to perform analysis and the utility of other platelet parameters have not been fully assessed.
Objectives
To validate Plateletworks ADP on the ProCyte Dx, to investigate the utility of various platelet parameters using Plateletworks ADP, and determine the ideal time to perform analysis. Animals Twenty healthy cats recruited from the general population used for transference of reference intervals to a new analyzer, and 10 cats receiving clopidogrel to determine clopidogrel effect.
Methods
Plateletworks ADP using the ProCyte Dx and ADVIA 2120i analyzer was run simultaneously in both healthy cats and cats receiving clopidogrel, and CBC results at different timepoints were compared between analyzers.
Results
Aggregation was significantly different (P < .001) between analyzers. Cohen's kappa showed almost perfect agreement for determination of clopidogrel effect, and the area under the curve of the receiver operating characteristic was 1.0. Lower limits of the aggregation reference interval in healthy cats were 28.8% on the ProCyte Dx and 12.5% on the ADVIA 2120i. Coefficients of variation for platelet parameters were not different between analyzers. No significant changes in mean platelet volume, plateletcrit, large platelets, and mean platelet component were identified. No significant change in aggregation was observed within the first hour after phlebotomy. Conclusions and Clinical Importance Our study validated the Plateletworks ADP system on the ProCyte Dx analyzer. Samples may be analyzed up to 1 h after collection.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
- Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
ORCID profiles: Matthew R Kornya, Shauna L Blois
Funding
- Ontario Veterinary College Pet Trust
- OVC Pet Trust
Cite
APA
Kornya, M. R., Abrams-Ogg, A. C. G., Blois, S. L., & Wood, R. D. (2023). Validation of Plateletworks ADP for the ProCyte Dx analyzer. Journal of Veterinary Internal Medicine. https://doi.org/10.1111/jvim.16670
Vancouver
Kornya MR, Abrams-Ogg ACG, Blois SL, Wood RD. Validation of Plateletworks ADP for the ProCyte Dx analyzer. Journal of Veterinary Internal Medicine. 2023. doi:10.1111/jvim.16670
BibTeX
@article{Kornya2023,
author = {Kornya, Matthew R and Abrams-Ogg, Anthony C G and Blois, Shauna L and Wood, R Darren},
title = {Validation of Plateletworks ADP for the ProCyte Dx analyzer},
journal = {Journal of Veterinary Internal Medicine},
year = {2023},
doi = {10.1111/jvim.16670}
}
EUVIMED