Platelet function analyzer‐200 closure curve analysis and assessment of flow‐obstructed samples
Veterinary Clinical Pathology · 2023
DOI: 10.1111/vcp.13260 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Veterinary Clinical Pathology, 2023. Verfasst von Matthew R Kornya und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada. Hauptthemen laut MEDLINE: Platelet Aggregation Inhibitors, Ticlopidine. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: OVC Pet Trust.
Abstract (Originalsprache)
Background
The Platelet function analyzer‐200 can determine the effect of clopidogrel in cats. Flow obstruction is an error that causes uninterpretable results. Closure curves and parameters initial flow rate (IF) and total volume (TV) are displayed by the PFA‐200 and may allow interpretation of results in cases of flow obstruction. The primary hemostasis components (PHC) are calculated values that normalize these parameters.
Objectives
To determine if closure curves and research parameters allow detecting the effect of clopidogrel in cases of flow obstruction.
Methods
A review of closure curves identified those with flow obstruction and paired analysis that did not. Non‐flow–obstructed curves were used to categorize curves with respect to clopidogrel effects. IF, TV, PHC(1), and PHC(2) were evaluated to determine if these could be used to categorize if a sample exhibited the effects of clopidogrel. Curves were visually analyzed, and characteristics identified that were more common with or without the effect of clopidogrel. Visual analysis of curves was performed by blinded observers to determine if a visual analysis was able to predict the effect of clopidogrel.
Results
Analysis of parameters was able to predict closure or non‐closure in flow‐obstructed curves. TV, PHC(1), and PHC(2) had area under the curve of the receiver operating characteristics of 0.79, 0.79, and 0.87. Visual curve analysis was unable to predict closure, with an average accuracy of only 55%, among three reviewers. Agreement between reviewers was poor (Fleiss' Kappa 0.06).
Conclusions
Visual curve analysis was unable to determine the effect of clopidogrel in flow‐obstructed samples. Numerical parameters were able to detect the effect of clopidogrel with a high degree of accuracy in flow‐obstructed samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
- Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
ORCID-Profile: Matthew R Kornya, Anthony C G Abrams-Ogg, Shauna L Blois
Förderung
- OVC Pet Trust
Zitieren
APA
Kornya, M. R., Abrams-Ogg, A. C. G., Blois, S. L., & Wood, R. D. (2023). Platelet function analyzer‐200 closure curve analysis and assessment of flow‐obstructed samples. Veterinary Clinical Pathology. https://doi.org/10.1111/vcp.13260
Vancouver
Kornya MR, Abrams-Ogg ACG, Blois SL, Wood RD. Platelet function analyzer‐200 closure curve analysis and assessment of flow‐obstructed samples. Veterinary Clinical Pathology. 2023. doi:10.1111/vcp.13260
BibTeX
@article{Kornya2023,
author = {Kornya, Matthew R and Abrams-Ogg, Anthony C G and Blois, Shauna L and Wood, R Darren},
title = {Platelet function analyzer‐200 closure curve analysis and assessment of flow‐obstructed samples},
journal = {Veterinary Clinical Pathology},
year = {2023},
doi = {10.1111/vcp.13260}
}
EUVIMED