Relative transmitted‐dose reduction of 3D‐printed and elastomeric dental radiotherapy spacers at different thicknesses
Journal of Prosthodontics · 03.11.2026
DOI: 10.1111/jopr.70263 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 03.11.2026. Verfasst von Wisarut Prawatvatchara und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Faculty Research Grant, Faculty of Dentistry, Chulalongkorn University, Bangkok.
Abstract (Originalsprache)
Purpose
To evaluate the radiation dose reduction of different materials for intraoral radiotherapy prostheses and spacers with different thicknesses. Materials and Methods Three additively manufactured resins—KeySplint Hard (3D‐Hard), Temporary CB Resin (3D‐TCB), and Saremco Print CROWNTEC (3D‐PCB)—and three elastomeric materials—putty‐type polyvinyl siloxane (PVS‐P), light‐body polyvinyl siloxane (PVS‐L), and polyether (PE)—were prepared with two thicknesses (5 and 10 mm, n = 5 per group). Rectangular specimens were fabricated and positioned over an ionization chamber in a solid–water phantom and measured 15 times with a 6 × 8 cm 2 field. The relative transmitted dose reduction was calculated against the bracketed no‐specimen reference values. Statistical analysis was done using two‐way analysis of variance followed by Games–Howell multiple comparisons.
Results
Material and thickness significantly affected the relative transmitted dose reduction ( p < 0.05), whereas their interaction was not significant ( p > 0.05). PVS‐P had significantly higher transmitted dose reduction than other materials, regardless of material thickness (3.50% ± 0.21% at 5 mm and 5.57% ± 0.43% at 10 mm). Among the additively manufactured resins, 3D‐PCB demonstrated higher transmitted dose reduction, where a significant effect was found at 10 mm thickness. At 5 mm, no significant difference was observed among three additively manufactured resins. However, at 10 mm, 3D‐PCB (3.83% ± 0.98%) produced significantly greater reduction than 3D‐Hard (3.06% ± 1.05%) and 3D‐TCB (3.13% ± 0.98%). For material thickness, the 10‐mm specimens produced greater reduction than the 5‐mm specimens.
Conclusions
Under the tested phantom and irradiation conditions, material and thickness influenced the relative transmitted‐dose reduction. The highest transmitted dose reduction was observed in PVS‐P. However, the effects were modest and thickness‐ dependent. These setup‐specific effects do not establish intrinsic material attenuation or clinical tissue protection.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
- Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
- Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.
- Maxillofacial Prosthetics Services, Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.
- Department of Operative Dentistry and Dental Materials Research and Development Center, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
- Clinic of Gerodontology and Special Care Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland.
ORCID-Profile: Wisarut Prawatvatchara, Tarnsai Tantiniramai, Thireeya Apasrawirote, Apinya Limvisitsakul, Pipop Saikaew, Cheewin Towithelertkul, Dusit Nantanapiboon
Förderung
- Faculty Research Grant
- Faculty of Dentistry, Chulalongkorn University, Bangkok
Zitieren
APA
Prawatvatchara, W., Tantiniramai, T., Apasrawirote, T., Limvisitsakul, A., Saikaew, P., Towithelertkul, C., & Nantanapiboon, D. (2026). Relative transmitted‐dose reduction of 3D‐printed and elastomeric dental radiotherapy spacers at different thicknesses. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70263
Vancouver
Prawatvatchara W, Tantiniramai T, Apasrawirote T, Limvisitsakul A, Saikaew P, Towithelertkul C, et al. Relative transmitted‐dose reduction of 3D‐printed and elastomeric dental radiotherapy spacers at different thicknesses. Journal of Prosthodontics. 2026. doi:10.1111/jopr.70263
BibTeX
@article{Prawatvatchara2026,
author = {Prawatvatchara, Wisarut and Tantiniramai, Tarnsai and Apasrawirote, Thireeya and Limvisitsakul, Apinya and Saikaew, Pipop and Towithelertkul, Cheewin and Nantanapiboon, Dusit},
title = {Relative transmitted‐dose reduction of 3D‐printed and elastomeric dental radiotherapy spacers at different thicknesses},
journal = {Journal of Prosthodontics},
year = {2026},
doi = {10.1111/jopr.70263}
}
EUVIMED