EUVIMEDEUVIMED entdecken
Crossref

Complete arch digital implant scans in the edentulous maxilla: Trueness and time efficiency based on scan body height, splinting, location, and scanner system

Cecilia Santos Galvao, Fabiana Silveira Ramalho Moreira, Annie Karoline Bezerra de Medeiros, Pamela TaynÁ Matias Bezerra, Martin Schimmel, Burak Yilmaz, Adriana da Fonte Porto Carreiro

The Journal of Prosthetic Dentistry · 2026-07 · 136 (1) · e280-e289

DOI: 10.1016/j.prosdent.2026.03.014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-07. Verfasst von Cecilia Santos Galvao und 6 weiteren Autor:innen. Beteiligte Einrichtung: PhD student, Department of Prosthodontics, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil. Hauptthemen laut MEDLINE: Maxilla, Jaw, Edentulous, Dental Implants, Computer-Aided Design. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Coordination for the improvement of Higher Education Personnel.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM Accurate digital scans of edentulous arches remain challenging. Combined effects of scan body height, splinting, location, and scanner on complete arch implant trueness have not been clarified. PURPOSE The purpose of this in vitro study was to evaluate scan body height, splinting, implant location (anterior/posterior), and 3 intraoral scanners on the trueness of 6-implant edentulous maxillary scans. MATERIAL AND METHODS Polyetheretherketone (PEEK) scan bodies with cylindrical geometry and 3 different heights (4.5 mm, 6 mm, 8 mm) were tightened on straight mini-unit abutments on 6 Morse implants in a 3-dimensionally (3D) printed resin model. Scans were performed splinted and nonsplinted using 3 different intraoral scanners (PrimeScan [PS]; TRIOS 5 [TR]; Infinite [IF]). Deviations at implant locations were quantified in micrometers. Trueness analysis was measured by overlaying scans in the Geomagic X Design software program. Deviations were quantified by root mean square (RMS) values. Statistical analysis was performed in Jamovi (v.2.3), including normality assessment (Shapiro-Wilk) and nonparametric comparisons using the Kruskal-Wallis and Mann-Whitney U tests with Dwass, Steel, Critchlow-Fligner (DSCF) Multiple Comparisons tests (α=.05). RESULTS Scan body height significantly affected trueness in all scanner groups (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MaxillaJaw, EdentulousDental ImplantsComputer-Aided DesignDental ArchHumansImaging, Three-DimensionalPrinting, Three-DimensionalBenzophenonesDental Prosthesis DesignPolyether CompoundsIn Vitro TechniquesPolymers

Substanzen

Dental ImplantsBenzophenonesPolyether CompoundspolyetheretherketonePolymers

Autor:innen und Institutionen

  • PhD student, Department of Prosthodontics, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.
  • Master's student, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.
  • PhD Researcher, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.
  • Professor, Division of Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Professor, Department of Reconstructive Dentistry and Gerodontology, University of Bern, Bern, Switzerland; Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University…
  • Full Professor, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil. Electronic address: adriana.carreiro@ufrn.br.

Förderung

  • Coordination for the improvement of Higher Education Personnel

Zitieren

APA

Galvao, C. S., Moreira, F. S. R., Medeiros, A. K. B., Bezerra, P. T. M., Schimmel, M., Yilmaz, B., & Carreiro, A. D. F. P. (2026). Complete arch digital implant scans in the edentulous maxilla: Trueness and time efficiency based on scan body height, splinting, location, and scanner system. The Journal of Prosthetic Dentistry, 136(1), e280-e289. https://doi.org/10.1016/j.prosdent.2026.03.014

Vancouver

Galvao CS, Moreira FSR, Medeiros AKB, Bezerra PTM, Schimmel M, Yilmaz B, et al. Complete arch digital implant scans in the edentulous maxilla: Trueness and time efficiency based on scan body height, splinting, location, and scanner system. The Journal of Prosthetic Dentistry. 2026;136(1):e280-e289. doi:10.1016/j.prosdent.2026.03.014

BibTeX
@article{Galvao2026,
  author = {Galvao, Cecilia Santos and Moreira, Fabiana Silveira Ramalho and Medeiros, Annie Karoline Bezerra de and Bezerra, Pamela TaynÁ Matias and Schimmel, Martin and Yilmaz, Burak and Carreiro, Adriana da Fonte Porto},
  title = {Complete arch digital implant scans in the edentulous maxilla: Trueness and time efficiency based on scan body height, splinting, location, and scanner system},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  volume = {136},
  number = {1},
  pages = {e280--e289},
  doi = {10.1016/j.prosdent.2026.03.014}
}
Kostenlos starten →