EUVIMEDEUVIMED entdecken
Crossref

Flexural properties and fatigue limit of 3D‐printed and milled resin‐based materials

Neimar Sartori iD, Said Arturo Sanchez, Dayane Oliveira iD, Sherif Hosney iD, Panagiotis Zoidis iD, William Martin iD, Luiz Gonzaga iD, Mateus G Rocha iD

Journal of Prosthodontics · 2025

DOI: 10.1111/jopr.13837 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, 2025. Verfasst von Neimar Sartori und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Prosthodontics, Department of Restorative Dental Sciences, University of Florida College of Dentistry, Gainesville, Florida, USA. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Composite Resins, Flexural Strength, Dental Materials. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Center for Dental Biomaterials, Center for Implant Dentistry, University of Florida, College of Dentistry.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to evaluate the flexural strength (FS), flexural modulus (FM), and fatigue limit (FL) of 3D‐printed resin‐based polymers and composites and compare them to 3D‐printed composites. Materials and Methods A bar‐shaped specimen (25 × 2 × 2 mm) was CAD designed according to ISO 4049:2019, and 60 duplicates of the 3D model were nested at a 45‐degree angle with the printing platform and 3D‐printed with three materials: denture teeth resin (Denture Teeth, Formlabs), temporary crown and bridge resin (Temporary CB, Formlabs), and composite (Flexcera Smile Ultra+, Desktop Health). The 3D model was also imported into a dental CAM software, duplicated 60 times, nested, and milled from a 3D‐milled composite puck (Ivotion Denture Teeth, Ivoclar). All specimens were post‐processed following the manufacturer's recommendation. The specimens were then subjected to a three‐point bending test until failure using a Universal Testing Machine at a crosshead speed of 0.75 mm/min, and FS and FM were calculated. The remaining thirty specimens were tested for Fatigue Limit using the staircase approach starting at 50% FS maximum up to 1.2 M cycles at 10 Hz. The data were analyzed using one‐way ANOVA and the Weibull distribution ( α = 0.05).

Results

The results showed that Ivotion and Flexcera had higher FS (110.3 ± 7.1 MPa and 107.6 ± 6.4 MPa, respectively) and FM (3.3 ± 0.1 GPa and 3.0 ± 0.2 GPa, respectively) compared to the 3D‐printed Denture Teeth (FS = 66.4 ± 18.5 MPa and FM = 1.8 ± 0.1 GPa) and Temporary CB (FS = 79.6 ± 12.1 MPa and FM = 2.7 ± 0.4 GPa). Weibull analysis showed that the Ivotion and Flexcera had a more uniform and narrower spatial distribution of defects ( m : 27.98 and 29.19) than the printed materials, which had m values of 8.17 and 4.11 for Temporary CB and Denture Teeth, respectively. Although no differences were found in the static properties (FS and FM) between Ivotion and Flexcera, Ivotion presented a higher endurance limit than Flexcera (51.43 vs. 40.95 MPa). The Temporary CB presented 21.08 MPa and Denture Teeth presented 17.80 MPa of endurance limit.

Conclusions

3D‐milled (Ivotion Denture Teeth) and 3D‐printed (Flexcera Smile Ultra+) composites outperformed 3D‐printed resins (Formlabs Denture Teeth and Temporary Crown & Bridge) in terms of flexural properties and fatigue resistance. 3D‐milled (Ivotion) and 3D‐printed (Flexcera) composites exhibited similar flexural properties, but 3D‐milled composites showed a 25% higher fatigue endurance limit, suggesting improved clinical longevity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalComposite ResinsFlexural StrengthDental MaterialsMaterials TestingDental Stress AnalysisComputer-Aided DesignHumans

Stichwörter der Autor:innen

3D‐milled materials3D‐printed materialsCAD‐CAMDenture TeethEndurance LimitFatigueFlexural StrengthMechanical PropertiesModulusPMMAPolymersWeibulladditive manufacturingsubtractive manufacturing

Substanzen

Composite ResinsDental Materials

Autor:innen und Institutionen

  • Division of Prosthodontics, Department of Restorative Dental Sciences, University of Florida College of Dentistry, Gainesville, Florida, USA.
  • Center for Dental Biomaterials, Department of Restorative Dental Science, College of Dentistry, University of Florida, Gainesville, Florida, USA.
  • Center for Implant Dentistry, Department of Oral Maxillofacial Surgery, University of Florida College of Dentistry, Gainesville, Florida, USA.
  • Department of Prosthodontics and Implantology, La Salle Bajío University, Leon, Mexico.

ORCID-Profile: Neimar Sartori, Dayane Oliveira, Sherif Hosney, Panagiotis Zoidis, William Martin, Luiz Gonzaga, Mateus G Rocha

Förderung

  • Center for Dental Biomaterials
  • Center for Implant Dentistry
  • University of Florida, College of Dentistry

Zitieren

APA

Sartori, N., Sanchez, S. A., Oliveira, D., Hosney, S., Zoidis, P., Martin, W., Gonzaga, L., & Rocha, M. G. (2025). Flexural properties and fatigue limit of 3D‐printed and milled resin‐based materials. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13837

Vancouver

Sartori N, Sanchez SA, Oliveira D, Hosney S, Zoidis P, Martin W, et al. Flexural properties and fatigue limit of 3D‐printed and milled resin‐based materials. Journal of Prosthodontics. 2025. doi:10.1111/jopr.13837

BibTeX
@article{Sartori2025,
  author = {Sartori, Neimar and Sanchez, Said Arturo and Oliveira, Dayane and Hosney, Sherif and Zoidis, Panagiotis and Martin, William and Gonzaga, Luiz and Rocha, Mateus G},
  title = {Flexural properties and fatigue limit of 3D‐printed and milled resin‐based materials},
  journal = {Journal of Prosthodontics},
  year = {2025},
  doi = {10.1111/jopr.13837}
}
Kostenlos starten →