Effect of customized abutment taper configuration on bone remodeling and peri‐implant tissue around implant‐supported single crown: A 3D nonlinear finite element study

Pongsakorn Poovarodom iD, Chaiy Rungsiyakull iD, Jarupol Suriyawanakul iD, Qing Li iD, Keiichi Sasaki iD, Nobuhiro Yoda iD, Pimduen Rungsiyakull iD

Journal of Prosthodontics · 2024

DOI: 10.1111/jopr.13776 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, 2024. Verfasst von Pongsakorn Poovarodom und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand. Hauptthemen laut MEDLINE: Finite Element Analysis, Bone Remodeling, Dental Implant-Abutment Design, Crowns. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: Chiang Mai University and Faculty of Dentistry, Chiang Mai University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The optimal configuration of a customized implant abutment plays a crucial role in promoting bone remodeling and maintaining the peri‐implant gingival contour. However, the biomechanical effects of abutment configuration on bone remodeling and peri‐implant tissue remain unclear. This study aimed to evaluate the influence of abutment taper configurations on bone remodeling and peri‐implant tissue. Materials and methods Five models with different abutment taper configurations (10°, 20°, 30°, 40°, and 50°) were analyzed using finite element analysis (FEA) to evaluate the biomechanical responses in peri‐implant bone and the hydrostatic pressure in peri‐implant tissue.

Results

The results demonstrated that the rate of increase in bone density was similar in all models. On the other hand, the hydrostatic pressure in peri‐implant gingiva revealed significantly different results. Model 10° showed the highest maximum and volume‐averaged hydrostatic pressures (69.31 and 4.5 mmHg), whereas Model 30° demonstrated the lowest values (57.83 and 3.88 mmHg) with the lowest excessive pressure area. The area of excessive hydrostatic pressure decreased in all models as the degree of abutment taper increased from 10° to 30°. In contrast, Models 40° and 50° exhibited greater hydrostatic pressure concentration at the cervical region.

Conclusion

In conclusion, the abutment taper configuration had a slight effect on bone remodeling but exerted a significant effect on the peri‐implant gingiva above the implant platform via hydrostatic pressure. Significant decreases in greatest and average hydrostatic pressures were observed in the peri‐implant tissues of Model 30°. However, the results indicate that implant abutment tapering wider than 40° could result in a larger area of excessive hydrostatic pressure in peri‐implant tissue, which could induce gingival recession.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisBone RemodelingDental Implant-Abutment DesignCrownsHumansDental Prosthesis, Implant-SupportedDental AbutmentsBiomechanical PhenomenaDental Implants, Single-ToothHydrostatic PressureGingiva

Stichwörter der Autor:innen

abutment taper configurationbone remodelingdental implanthydrostatic pressure analysisperi‐implant tissue

Autor:innen und Institutionen

  • Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand.
  • Department of Mechanical Engineering, Faculty of Engineering, Chiang Mai University, Muang, Chiang Mai, Thailand.
  • Faculty of Engineering, Department of Mechanical Engineering, Khon Kaen University, Nai Mueang, Thailand.
  • Faculty of Engineering, School of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, Australia.
  • Miyagi University, Taiwa, Japan.
  • Graduate School of Dentistry, Division of Prosthetic Dentistry, Tohoku University, Sendai, Japan.

ORCID-Profile: Pongsakorn Poovarodom, Chaiy Rungsiyakull, Jarupol Suriyawanakul, Qing Li, Keiichi Sasaki, Nobuhiro Yoda, Pimduen Rungsiyakull

Förderung

  • Chiang Mai University and Faculty of Dentistry, Chiang Mai University

Zitieren

APA

Poovarodom, P., Rungsiyakull, C., Suriyawanakul, J., Li, Q., Sasaki, K., Yoda, N., & Rungsiyakull, P. (2024). Effect of customized abutment taper configuration on bone remodeling and peri‐implant tissue around implant‐supported single crown: A 3D nonlinear finite element study. Journal of Prosthodontics. https://doi.org/10.1111/jopr.13776

Vancouver

Poovarodom P, Rungsiyakull C, Suriyawanakul J, Li Q, Sasaki K, Yoda N, et al. Effect of customized abutment taper configuration on bone remodeling and peri‐implant tissue around implant‐supported single crown: A 3D nonlinear finite element study. Journal of Prosthodontics. 2024. doi:10.1111/jopr.13776

BibTeX
@article{Poovarodom2024,
  author = {Poovarodom, Pongsakorn and Rungsiyakull, Chaiy and Suriyawanakul, Jarupol and Li, Qing and Sasaki, Keiichi and Yoda, Nobuhiro and Rungsiyakull, Pimduen},
  title = {Effect of customized abutment taper configuration on bone remodeling and peri‐implant tissue around implant‐supported single crown: A 3D nonlinear finite element study},
  journal = {Journal of Prosthodontics},
  year = {2024},
  doi = {10.1111/jopr.13776}
}
Kostenlos starten →