Effect of Thermal Cycling on the Flexural Strength and Hardness of New‐Generation Denture Base Materials

Gülce Çakmak iD, Mustafa Borga Donmez iD, Canan Akay iD, Samir Abou-Ayash iD, Martin Schimmel, Burak Yilmaz iD

Journal of Prosthodontics · 2023-04 · 32 (S1) · 81-86

DOI: 10.1111/jopr.13615 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 04.11.2022. Verfasst von Gülce Çakmak und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland. Hauptthemen laut MEDLINE: Flexural Strength, Graphite. Die Arbeit wurde bisher 48-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the flexural strength and Vickers microhardness of different CAD‐CAM denture base materials. Materials and methods Sixty rectangular specimens (64 × 10 × 3.3 ± 0.2 mm) were fabricated from 3 different denture base materials (G‐CAM, Graphene‐reinforced polymethylmethacrylate, GC), Ivotion Base (Prepolymerized polymethylmethacrylate, IV), and Denturetec (3D‐printed resin, DT) either by using additive (DT) or subtractive manufacturing (IV and GC). Specimens of each group were divided into 2 subgroups (thermal cycled or nonthermal cycled, n = 10/group). Nonthermal cycled specimens were stored in distilled water at 37°C for 24 hours and subjected to 3‐point flexural strength test with a universal testing machine. Thermal cycled specimens were initially evaluated for Vickers microhardness and subjected to thermal cycling (10,000 cycles at 5–55°C). Vickers microhardness values were remeasured, and the specimens were subjected to 3‐point flexural strength test. Data were analyzed by using 2‐way analysis of variance and Bonferroni‐corrected Tukey honestly significant difference tests (α = 0.05).

Results

Material type and condition significantly affected flexural strength ( p ≤ 0.004), whereas their interaction was nonsignificant ( p = 0.778). Overall flexural strength of the materials in decreasing order was GC, IV, and DT ( p < 0.001), regardless of the condition. Material had a higher effect on flexural strength (ηp 2 = 0.731) than thermal cycling (ηp 2 = 0.142). The effect of the interaction between the material type and thermal cycling on Vickers microhardness was significant ( p < 0.001). GC had the highest microhardness before and after thermal cycling ( p < 0.001). IV had higher microhardness than DT before thermal cycling ( p < 0.001). However, DT and IV showed similar microhardness after thermal cycling ( p = 0.665). Thermal cycling decreased the microhardness of GC and IV ( p ≤ 0.022), whereas its effect on DT's microhardness was nonsignificant ( p = 0.538). Material type had the highest effect on microhardness (ηp 2 = 0.864) followed by the interaction between the main factors (ηp 2 = 0.258).

Conclusions

Graphene‐reinforced polymethylmethacrylate had the highest flexural strength and Vickers microhardness values, regardless of thermal cycling. Thermal cycling reduced the flexural strength of all resins. Thermal cycling reduced the microhardness of milled polymethylmethacrylate, but not that of 3D‐printed resin.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flexural StrengthGraphiteHardnessPolymethyl MethacrylateDenture BasesMaterials TestingSurface Properties

Stichwörter der Autor:innen

Additive manufacturingdenture baseflexural strengthmicrohardnessthermal cycling

Substanzen

Polymethyl MethacrylateGraphite

Autor:innen und Institutionen

  • Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey.
  • Department of Prosthodontics, Faculty of Dentistry, Osmangazi University, Eskisehir, Turkey.
  • Translational Medicine Research and Clinical Center, Osmangazi University, Eskisehir, Turkey.
  • Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
  • Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland.

ORCID-Profile: Gülce Çakmak, Mustafa Borga Donmez, Canan Akay, Samir Abou-Ayash, Burak Yilmaz

Zitieren

APA

Çakmak, G., Donmez, M. B., Akay, C., Abou-Ayash, S., Schimmel, M., & Yilmaz, B. (2023). Effect of Thermal Cycling on the Flexural Strength and Hardness of New‐Generation Denture Base Materials. Journal of Prosthodontics, 32(S1), 81-86. https://doi.org/10.1111/jopr.13615

Vancouver

Çakmak G, Donmez MB, Akay C, Abou-Ayash S, Schimmel M, Yilmaz B. Effect of Thermal Cycling on the Flexural Strength and Hardness of New‐Generation Denture Base Materials. Journal of Prosthodontics. 2023;32(S1):81-86. doi:10.1111/jopr.13615

BibTeX
@article{akmak2023,
  author = {Çakmak, Gülce and Donmez, Mustafa Borga and Akay, Canan and Abou-Ayash, Samir and Schimmel, Martin and Yilmaz, Burak},
  title = {Effect of Thermal Cycling on the Flexural Strength and Hardness of New‐Generation Denture Base Materials},
  journal = {Journal of Prosthodontics},
  year = {2023},
  volume = {32},
  number = {S1},
  pages = {81--86},
  doi = {10.1111/jopr.13615}
}
Kostenlos starten →