EUVIMEDSkopri EUVIMED
Scoping Review

Automation of Ultrasonographic Optic Nerve Sheath Diameter Measurement: A Scoping Review

César E Escamilla-Ocañas iD, Noelia C Morales-Cardona, Hersh Sagreiya, Alireza Akhbardeh, Mohammad I Hirzallah

Journal of Neuroimaging · 2025

DOI: 10.1111/jon.70017 ↗

At a glance

Scoping Review in Journal of Neuroimaging, 2025. Written by César E Escamilla-Ocañas and 4 co-authors. Institution: Department of Neurocritical Care, Massachusetts General Hospital, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA. Major MEDLINE topics: Optic Nerve. Cited 4 times so far (Crossref); 42 references.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Intracranial pressure (ICP) monitoring is a cornerstone of neurocritical care in managing severe brain injury. However, current invasive ICP monitoring methods carry significant risks, including infection and intracranial hemorrhage, and are contraindicated in certain clinical situations. Additionally, these methods are not universally available. Optic nerve sheath diameter (ONSD) measurement presents a promising noninvasive alternative for ICP monitoring, though its clinical adoption has been limited due to its operator dependence and inconsistencies in imaging acquisition and measurement techniques. Automating both ONSD image acquisition and measurement could enhance accuracy and reliability, thereby improving its utility as a noninvasive ICP estimation tool. A range of image analysis and machine learning (ML) techniques have been applied to address these challenges. In this paper, we provide a narrative review of the current literature on ONSD automation, examining the strengths and limitations of classical image analysis and ML models in improving ONSD‐based ICP assessment.

Subjects

MeSH terms (MEDLINE)

Optic NerveHumansIntracranial PressureUltrasonographyReproducibility of ResultsIntracranial HypertensionMachine Learning

Author keywords

automationimage processingintracranial pressure (ICP)machine learning (ML)optic nerve sheath diameter (ONSD)ultrasound

Authors and institutions

  • Department of Neurocritical Care, Massachusetts General Hospital, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
  • Department of Neurology, Baylor College of Medicine, Houston, Texas, USA.
  • Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Department of Diagnostic and Interventional Imaging, University of Texas at Houston, Houston, Texas, USA.
  • Center for Space Medicine, Baylor College of Medicine, Houston, Texas, USA.

ORCID profiles: César E Escamilla-Ocañas

Cite

APA

Escamilla-Ocañas, C. E., Morales-Cardona, N. C., Sagreiya, H., Akhbardeh, A., & Hirzallah, M. I. (2025). Automation of Ultrasonographic Optic Nerve Sheath Diameter Measurement: A Scoping Review. Journal of Neuroimaging. https://doi.org/10.1111/jon.70017

Vancouver

Escamilla-Ocañas CE, Morales-Cardona NC, Sagreiya H, Akhbardeh A, Hirzallah MI. Automation of Ultrasonographic Optic Nerve Sheath Diameter Measurement: A Scoping Review. Journal of Neuroimaging. 2025. doi:10.1111/jon.70017

BibTeX
@article{EscamillaOcaas2025,
  author = {Escamilla-Ocañas, César E and Morales-Cardona, Noelia C and Sagreiya, Hersh and Akhbardeh, Alireza and Hirzallah, Mohammad I},
  title = {Automation of Ultrasonographic Optic Nerve Sheath Diameter Measurement: A Scoping Review},
  journal = {Journal of Neuroimaging},
  year = {2025},
  doi = {10.1111/jon.70017}
}
Start for free →