Scoping Review in der Zeitschrift Journal of Neuroimaging, 2025. Verfasst von César E Escamilla-Ocañas und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurocritical Care, Massachusetts General Hospital, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Optic Nerve. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 42 Literaturangaben.
Abstract (Originalsprache)
Intracranial pressure (ICP) monitoring is a cornerstone of neurocritical care in managing severe brain injury. However, current invasive ICP monitoring methods carry significant risks, including infection and intracranial hemorrhage, and are contraindicated in certain clinical situations. Additionally, these methods are not universally available. Optic nerve sheath diameter (ONSD) measurement presents a promising noninvasive alternative for ICP monitoring, though its clinical adoption has been limited due to its operator dependence and inconsistencies in imaging acquisition and measurement techniques. Automating both ONSD image acquisition and measurement could enhance accuracy and reliability, thereby improving its utility as a noninvasive ICP estimation tool. A range of image analysis and machine learning (ML) techniques have been applied to address these challenges. In this paper, we provide a narrative review of the current literature on ONSD automation, examining the strengths and limitations of classical image analysis and ML models in improving ONSD‐based ICP assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurocritical Care, Massachusetts General Hospital, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
- Department of Neurology, Baylor College of Medicine, Houston, Texas, USA.
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Department of Diagnostic and Interventional Imaging, University of Texas at Houston, Houston, Texas, USA.
- Center for Space Medicine, Baylor College of Medicine, Houston, Texas, USA.
ORCID-Profile: César E Escamilla-Ocañas
Zitieren
APA
Escamilla-Ocañas, C. E., Morales-Cardona, N. C., Sagreiya, H., Akhbardeh, A., & Hirzallah, M. I. (2025). Automation of Ultrasonographic Optic Nerve Sheath Diameter Measurement: A Scoping Review. Journal of Neuroimaging. https://doi.org/10.1111/jon.70017
Vancouver
Escamilla-Ocañas CE, Morales-Cardona NC, Sagreiya H, Akhbardeh A, Hirzallah MI. Automation of Ultrasonographic Optic Nerve Sheath Diameter Measurement: A Scoping Review. Journal of Neuroimaging. 2025. doi:10.1111/jon.70017
BibTeX
@article{EscamillaOcaas2025,
author = {Escamilla-Ocañas, César E and Morales-Cardona, Noelia C and Sagreiya, Hersh and Akhbardeh, Alireza and Hirzallah, Mohammad I},
title = {Automation of Ultrasonographic Optic Nerve Sheath Diameter Measurement: A Scoping Review},
journal = {Journal of Neuroimaging},
year = {2025},
doi = {10.1111/jon.70017}
}
EUVIMED