Blood Flow Velocities as Determined by Real‐Time Phase‐Contrast MRI in Patients With Carotid Artery Stenosis

Deborah Bochert iD, Sabine Hofer, Peter Dechent, Jens Frahm, Mathias Bähr, Jan Liman, Ilko Maier iD

Journal of Neuroimaging · 2025

DOI: 10.1111/jon.70016 ↗

At a glance

Journal article in Journal of Neuroimaging, 2025. Written by Deborah Bochert and 6 co-authors. Institution: Department of Neurology, University Medical Center Göttingen, Gottingen, Niedersachsen, Germany. Major MEDLINE topics: Carotid Stenosis, Magnetic Resonance Angiography, Magnetic Resonance Imaging. Cited 1 times so far (Crossref); 26 references. The full text is freely available (open access, CC BY 4.0).

ResumoSubjectsDados bibliográficosCiteRelated studies

Abstract (original language)

Background and Purpose Real‐time phase‐contrast (RT‐PC) flow MRI can be used to determine quantitative flow parameters throughout the vessel lumen of extracranial, brain‐supplying arteries. Its potential value in the diagnostic workup of patients with carotid artery stenosis has not been evaluated.

Methods

RT‐PC flow MRI was performed in 10 patients with carotid stenosis in comparison to conventional neurovascular ultrasound (nvUS). Peak systolic velocity, end‐diastolic velocity, mean flow velocity, and flow volumes have been evaluated by RT‐PC flow MRI. Measurements have been performed at standardized sites along the common, internal, and external carotid arteries on both sides and at the maximum of the carotid stenosis.

Results

Blood flow velocities were significantly lower with RT‐PC flow MRI compared to nvUS and not consistently correlated between both methods. Within the maximum of the carotid stenosis, RT‐PC flow MRI showed implausible flow velocity reductions compared to nvUS. In contrast, the flow volumes determined by RT‐PC flow MRI—with exception of the stenosis maximum—were comparable with nvUS and significantly correlated in the prestenotic common carotid artery.

Conclusion

RT‐PC flow MRI does not appear to be suitable for quantifying blood flow velocities and volumes in the patients with carotid stenosis compared to nvUS. Apart from the lower temporal resolution of RT‐PC MRI, the lack of correlation of blood flow velocities might be ascribed to the prevalence of nonlaminar flow within and behind the stenosis, which violates a general prerequisite for valid flow velocity measurements by PC MRI.

Subjects

MeSH terms (MEDLINE)

Carotid StenosisMagnetic Resonance AngiographyMagnetic Resonance ImagingHumansBlood Flow VelocityMaleFemaleAgedMiddle AgedReproducibility of ResultsSensitivity and SpecificityComputer Systems

Author keywords

atherosclerosisblood flowcarotid stenosisreal‐time phase‐contrast MRI

Authors and institutions

  • Department of Neurology, University Medical Center Göttingen, Gottingen, Niedersachsen, Germany.
  • Department of Cognitive Neurology, University Medical Center Göttingen, Gottingen, Niedersachsen, Germany.
  • Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Gottingen, Niedersachsen, Germany.
  • Department of Neurology, Paracelsus Medical School, Nuremberg, Bayern, Germany.

ORCID profiles: Deborah Bochert, Ilko Maier

Cite

APA

Bochert, D., Hofer, S., Dechent, P., Frahm, J., Bähr, M., Liman, J., & Maier, I. (2025). Blood Flow Velocities as Determined by Real‐Time Phase‐Contrast MRI in Patients With Carotid Artery Stenosis. Journal of Neuroimaging. https://doi.org/10.1111/jon.70016

Vancouver

Bochert D, Hofer S, Dechent P, Frahm J, Bähr M, Liman J, et al. Blood Flow Velocities as Determined by Real‐Time Phase‐Contrast MRI in Patients With Carotid Artery Stenosis. Journal of Neuroimaging. 2025. doi:10.1111/jon.70016

BibTeX
@article{Bochert2025,
  author = {Bochert, Deborah and Hofer, Sabine and Dechent, Peter and Frahm, Jens and Bähr, Mathias and Liman, Jan and Maier, Ilko},
  title = {Blood Flow Velocities as Determined by Real‐Time Phase‐Contrast MRI in Patients With Carotid Artery Stenosis},
  journal = {Journal of Neuroimaging},
  year = {2025},
  doi = {10.1111/jon.70016}
}
Start for free →