Blood Flow Velocities as Determined by Real‐Time Phase‐Contrast MRI in Patients With Carotid Artery Stenosis
Journal of Neuroimaging · 2025
DOI: 10.1111/jon.70016 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neuroimaging, 2025. Verfasst von Deborah Bochert und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, University Medical Center Göttingen, Gottingen, Niedersachsen, Germany. Hauptthemen laut MEDLINE: Carotid Stenosis, Magnetic Resonance Angiography, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and Purpose Real‐time phase‐contrast (RT‐PC) flow MRI can be used to determine quantitative flow parameters throughout the vessel lumen of extracranial, brain‐supplying arteries. Its potential value in the diagnostic workup of patients with carotid artery stenosis has not been evaluated.
Methods
RT‐PC flow MRI was performed in 10 patients with carotid stenosis in comparison to conventional neurovascular ultrasound (nvUS). Peak systolic velocity, end‐diastolic velocity, mean flow velocity, and flow volumes have been evaluated by RT‐PC flow MRI. Measurements have been performed at standardized sites along the common, internal, and external carotid arteries on both sides and at the maximum of the carotid stenosis.
Results
Blood flow velocities were significantly lower with RT‐PC flow MRI compared to nvUS and not consistently correlated between both methods. Within the maximum of the carotid stenosis, RT‐PC flow MRI showed implausible flow velocity reductions compared to nvUS. In contrast, the flow volumes determined by RT‐PC flow MRI—with exception of the stenosis maximum—were comparable with nvUS and significantly correlated in the prestenotic common carotid artery.
Conclusion
RT‐PC flow MRI does not appear to be suitable for quantifying blood flow velocities and volumes in the patients with carotid stenosis compared to nvUS. Apart from the lower temporal resolution of RT‐PC MRI, the lack of correlation of blood flow velocities might be ascribed to the prevalence of nonlaminar flow within and behind the stenosis, which violates a general prerequisite for valid flow velocity measurements by PC MRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, University Medical Center Göttingen, Gottingen, Niedersachsen, Germany.
- Department of Cognitive Neurology, University Medical Center Göttingen, Gottingen, Niedersachsen, Germany.
- Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Gottingen, Niedersachsen, Germany.
- Department of Neurology, Paracelsus Medical School, Nuremberg, Bayern, Germany.
ORCID-Profile: Deborah Bochert, Ilko Maier
Zitieren
APA
Bochert, D., Hofer, S., Dechent, P., Frahm, J., Bähr, M., Liman, J., & Maier, I. (2025). Blood Flow Velocities as Determined by Real‐Time Phase‐Contrast MRI in Patients With Carotid Artery Stenosis. Journal of Neuroimaging. https://doi.org/10.1111/jon.70016
Vancouver
Bochert D, Hofer S, Dechent P, Frahm J, Bähr M, Liman J, et al. Blood Flow Velocities as Determined by Real‐Time Phase‐Contrast MRI in Patients With Carotid Artery Stenosis. Journal of Neuroimaging. 2025. doi:10.1111/jon.70016
BibTeX
@article{Bochert2025,
author = {Bochert, Deborah and Hofer, Sabine and Dechent, Peter and Frahm, Jens and Bähr, Mathias and Liman, Jan and Maier, Ilko},
title = {Blood Flow Velocities as Determined by Real‐Time Phase‐Contrast MRI in Patients With Carotid Artery Stenosis},
journal = {Journal of Neuroimaging},
year = {2025},
doi = {10.1111/jon.70016}
}
EUVIMED