EUVIMEDOpdag EUVIMED
ValidierungsstudieVergleichsstudieOpen access

Validation of bedside manual versus automated measurements of brain arterial diameters from MR angiography

Nicolas D Garzon-Mancera iD, Farid Khasiyev iD, Victor J Del Brutto, Antonio J Spagnolo Allende, Clinton B Wright, Mitchell Elkind, Tatjana Rundek, Oscar H Del Brutto iD, Jose Gutierrez

Journal of Neuroimaging · 2024

DOI: 10.1111/jon.13217 ↗

At a glance

Validierungsstudie in Journal of Neuroimaging, 2024. Written by Nicolas D Garzon-Mancera and 8 co-authors. Institution: Department of Neurology, Columbia University Irving Medical Center, New York, New York, USA. Major MEDLINE topics: Magnetic Resonance Angiography. Cited 1 times so far (Crossref); 22 references. The full text is freely available in PubMed Central. Funded by: NIA NIH HHS, National Institute on Aging.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background and Purpose Brain arterial luminal diameters are reliably measured with automated imaging software. Nonautomated imaging software alternatives such as a Picture Archiving Communication System are more common bedside tools used for manual measurement. This study is aimed at validating manual measurements against automated methods.

Methods

We randomly selected 600 participants from the Northern Manhattan Study (NOMAS) and 260 participants from the Atahualpa Project studied with 1.5 Tesla MR angiography. Using the Radiant measuring tool, three independent readers (general practitioner, neurology resident, and vascular neurologist) measured manually the diameter of arterial brain vessels. The same vessels were also measured by LKEB Automated Vessel Analysis (LAVA). We calculated the intraclass correlation coefficient (ICC) of each rater's diameters versus those obtained with LAVA.

Results

The ICC between diameters obtained by the general practitioner or the neurology resident compared to LAVA was excellent for both internal carotid arteries (ICA) and Basilar Arteries (BA) (ICC > .80 in all comparisons) in NOMAS. In the Atahualpa Project, ICC between diameters obtained by a vascular neurologist and LAVA was good for both ICA and BA (ICC > .60 in all comparisons). The ICCs for the measurements of the remaining arteries were moderate to poor.

Conclusion

Results suggest that manual measurements of ICA and BA diameters, but not MCA or ACA, are valid and could be used to identify dilated brain arteries at the bedside and for eventual selection of patients with dolichoectasia into clinical trials.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance AngiographyHumansMaleReproducibility of ResultsFemaleMiddle AgedAgedSensitivity and SpecificityPoint-of-Care SystemsImage Interpretation, Computer-AssistedPattern Recognition, AutomatedAlgorithmsCerebral ArteriesObserver Variation

Author keywords

brain arterial diametersdolichoectasiamagnetic resonance angiographyvalidation study

Authors and institutions

  • Department of Neurology, Columbia University Irving Medical Center, New York, New York, USA.
  • Department of Neurology, St. Louis University Hospital, St. Louis, Missouri, USA.
  • School of Medicine, University of Miami Miller, Miami, Florida, USA.
  • National Institutes of Health, Rockville, Maryland, USA.
  • School of Medicine and Research Center, Universidad Espiritu Santi, Samborondón, Ecuador.

ORCID profiles: Nicolas D Garzon-Mancera, Farid Khasiyev, Oscar H Del Brutto

Funding

  • NIA NIH HHS
  • National Institute on Aging

Cite

APA

Garzon-Mancera, N. D., Khasiyev, F., Del Brutto, V. J., Spagnolo Allende, A. J., Wright, C. B., Elkind, M., Rundek, T., Del Brutto, O. H., & Gutierrez, J. (2024). Validation of bedside manual versus automated measurements of brain arterial diameters from MR angiography. Journal of Neuroimaging. https://doi.org/10.1111/jon.13217

Vancouver

Garzon-Mancera ND, Khasiyev F, Del Brutto VJ, Spagnolo Allende AJ, Wright CB, Elkind M, et al. Validation of bedside manual versus automated measurements of brain arterial diameters from MR angiography. Journal of Neuroimaging. 2024. doi:10.1111/jon.13217

BibTeX
@article{GarzonMancera2024,
  author = {Garzon-Mancera, Nicolas D and Khasiyev, Farid and Del Brutto, Victor J and Spagnolo Allende, Antonio J and Wright, Clinton B and Elkind, Mitchell and Rundek, Tatjana and Del Brutto, Oscar H and Gutierrez, Jose},
  title = {Validation of bedside manual versus automated measurements of brain arterial diameters from MR angiography},
  journal = {Journal of Neuroimaging},
  year = {2024},
  doi = {10.1111/jon.13217}
}
Start for free →