EUVIMEDEUVIMED entdecken
Vergleichsstudie

Velocity-Selective arterial spin labeling (VSASL) for cerebral blood volume assessment in gliomas: comparison with VSASL based cerebral blood flow and dynamic susceptibility contrast MRI.

Yaoming Qu, Andong Ma, Xinran Yan, Xiaochan Ou, Xia Zou, Qihong Rui, Haitao Wen, Xianlong Wang, Dan Zhu, Qin Qin, Zhibo Wen

Neuroradiology · 2025

DOI: 10.1007/s00234-025-03751-6 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Neuroradiology, 2025. Verfasst von Yaoming Qu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Zhujiang Hospital of Southern Medical University, Guangzhou, China. Hauptthemen laut MEDLINE: Glioma, Brain Neoplasms, Cerebral Blood Volume, Magnetic Resonance Angiography. Die Arbeit nennt 48 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Cerebral blood volume (CBV) maps created using dynamic susceptibility contrast-enhanced perfusion weighted imaging (DSC-PWI) are valuable but may be limited by gadolinium contraindications in certain clinical scenarios. A noninvasive perfusion method for CBV assessment based on velocity-selective (VS) ASL has emerged. This study is to evaluate the performance of VSASL-derived CBV among glioma patients in clinical practice, comparing with the VSASL-based cerebral blood flow (CBF) and DSC-PWI. METHODS: Forty-eight patients with pathologically confirmed gliomas (mean age: 45 ± 13 years; 25 males; 25 in low-grade) underwent preoperative VSASL-CBV MRI. Lesion conspicuity on VSASL-CBV maps was visually scored (1-3) relative to surrounding parenchyma by two neuroradiologists. Relative maximum tumor blood volume (rTBV) and flow (rTBF) from VSASL and DSC-PWI were compared between low- and high-grade gliomas. Correlation and agreement between VSASL- and DSC-PWI-derived rTBV were assessed via linear regression and Bland-Altman analysis. Diagnostic performance for glioma grading was evaluated using ROC curves. RESULTS: VSASL-CBV maps demonstrated good lesion conspicuity (mean score: 2.26 ± 0.76; inter-reader weighted κ = 0.8). VSASL-rTBV strongly correlated with DSC-PWI-rTBV (R²=0.83, p < 0.001). Both VSASL and DSC-PWI metrics significantly distinguished low- from high-grade gliomas (p < 0.001). ROC analysis revealed that VSASL-rTBV achieved excellent diagnostic accuracy in glioma grading (AUC = 0.94), outperforming VSASL-rTBF (AUC = 0.89) and matching DSC-PWI-rTBV (AUC = 0.93). Sensitivity, predictive values, and accuracy of VSASL-rTBV were superior to VSASL-rTBF. CONCLUSION: VSASL provides accurate, noninvasive CBV quantification for glioma stratification, demonstrating diagnostic performance comparable to DSC-PWI. It offers a viable alternative in clinical settings where gadolinium contrast is contraindicated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GliomaBrain NeoplasmsCerebral Blood VolumeMagnetic Resonance AngiographyCerebrovascular CirculationBlood Volume DeterminationHumansMaleFemaleMiddle AgedSpin LabelsContrast MediaSensitivity and SpecificityAdultBlood Flow VelocityReproducibility of ResultsAgedImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

Cerebral blood volumeDiagnosis, differentialGliomaMagnetic resonance imagingPerfusion imaging

Substanzen

Spin LabelsContrast Media

Autor:innen und Institutionen

  • Department of Radiology, Zhujiang Hospital of Southern Medical University, Guangzhou, China.
  • Department of Radiology, The First People's Hospital of FoShan, FoShan, China.
  • Department of Radiology, The First Affiliated Hospital of Nanchang University, Nanchang, China.
  • The Johns Hopkins University School of Medicine, Baltimore, United States.
  • Kennedy Krieger Institute, Baltimore, United States.
  • Department of Radiology, Zhujiang Hospital of Southern Medical University, Guangzhou, China. zhibowen@163.com.

Zitieren

APA

Qu, Y., Ma, A., Yan, X., Ou, X., Zou, X., Rui, Q., Wen, H., Wang, X., Zhu, D., Qin, Q., & Wen, Z. (2025). Velocity-Selective arterial spin labeling (VSASL) for cerebral blood volume assessment in gliomas: comparison with VSASL based cerebral blood flow and dynamic susceptibility contrast MRI. Neuroradiology. https://doi.org/10.1007/s00234-025-03751-6

Vancouver

Qu Y, Ma A, Yan X, Ou X, Zou X, Rui Q, et al. Velocity-Selective arterial spin labeling (VSASL) for cerebral blood volume assessment in gliomas: comparison with VSASL based cerebral blood flow and dynamic susceptibility contrast MRI. Neuroradiology. 2025. doi:10.1007/s00234-025-03751-6

BibTeX
@article{Qu2025,
  author = {Qu, Yaoming and Ma, Andong and Yan, Xinran and Ou, Xiaochan and Zou, Xia and Rui, Qihong and Wen, Haitao and Wang, Xianlong and Zhu, Dan and Qin, Qin and Wen, Zhibo},
  title = {Velocity-Selective arterial spin labeling (VSASL) for cerebral blood volume assessment in gliomas: comparison with VSASL based cerebral blood flow and dynamic susceptibility contrast MRI},
  journal = {Neuroradiology},
  year = {2025},
  doi = {10.1007/s00234-025-03751-6}
}
Kostenlos starten →