EUVIMEDEUVIMED entdecken
ValidierungsstudieVergleichsstudieOpen Access

Validation of bedside manual versus automated measurements of brain arterial diameters from MR angiography

Nicolas D Garzon-Mancera iD, Farid Khasiyev iD, Victor J Del Brutto, Antonio J Spagnolo Allende, Clinton B Wright, Mitchell Elkind, Tatjana Rundek, Oscar H Del Brutto iD, Jose Gutierrez

Journal of Neuroimaging · 2024

DOI: 10.1111/jon.13217 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Neuroimaging, 2024. Verfasst von Nicolas D Garzon-Mancera und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Columbia University Irving Medical Center, New York, New York, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIA NIH HHS, National Institute on Aging.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Purpose Brain arterial luminal diameters are reliably measured with automated imaging software. Nonautomated imaging software alternatives such as a Picture Archiving Communication System are more common bedside tools used for manual measurement. This study is aimed at validating manual measurements against automated methods.

Methods

We randomly selected 600 participants from the Northern Manhattan Study (NOMAS) and 260 participants from the Atahualpa Project studied with 1.5 Tesla MR angiography. Using the Radiant measuring tool, three independent readers (general practitioner, neurology resident, and vascular neurologist) measured manually the diameter of arterial brain vessels. The same vessels were also measured by LKEB Automated Vessel Analysis (LAVA). We calculated the intraclass correlation coefficient (ICC) of each rater's diameters versus those obtained with LAVA.

Results

The ICC between diameters obtained by the general practitioner or the neurology resident compared to LAVA was excellent for both internal carotid arteries (ICA) and Basilar Arteries (BA) (ICC > .80 in all comparisons) in NOMAS. In the Atahualpa Project, ICC between diameters obtained by a vascular neurologist and LAVA was good for both ICA and BA (ICC > .60 in all comparisons). The ICCs for the measurements of the remaining arteries were moderate to poor.

Conclusion

Results suggest that manual measurements of ICA and BA diameters, but not MCA or ACA, are valid and could be used to identify dilated brain arteries at the bedside and for eventual selection of patients with dolichoectasia into clinical trials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyHumansMaleReproducibility of ResultsFemaleMiddle AgedAgedSensitivity and SpecificityPoint-of-Care SystemsImage Interpretation, Computer-AssistedPattern Recognition, AutomatedAlgorithmsCerebral ArteriesObserver Variation

Stichwörter der Autor:innen

brain arterial diametersdolichoectasiamagnetic resonance angiographyvalidation study

Autor:innen und Institutionen

  • Department of Neurology, Columbia University Irving Medical Center, New York, New York, USA.
  • Department of Neurology, St. Louis University Hospital, St. Louis, Missouri, USA.
  • School of Medicine, University of Miami Miller, Miami, Florida, USA.
  • National Institutes of Health, Rockville, Maryland, USA.
  • School of Medicine and Research Center, Universidad Espiritu Santi, Samborondón, Ecuador.

ORCID-Profile: Nicolas D Garzon-Mancera, Farid Khasiyev, Oscar H Del Brutto

Förderung

  • NIA NIH HHS
  • National Institute on Aging

Zitieren

APA

Garzon-Mancera, N. D., Khasiyev, F., Del Brutto, V. J., Spagnolo Allende, A. J., Wright, C. B., Elkind, M., Rundek, T., Del Brutto, O. H., & Gutierrez, J. (2024). Validation of bedside manual versus automated measurements of brain arterial diameters from MR angiography. Journal of Neuroimaging. https://doi.org/10.1111/jon.13217

Vancouver

Garzon-Mancera ND, Khasiyev F, Del Brutto VJ, Spagnolo Allende AJ, Wright CB, Elkind M, et al. Validation of bedside manual versus automated measurements of brain arterial diameters from MR angiography. Journal of Neuroimaging. 2024. doi:10.1111/jon.13217

BibTeX
@article{GarzonMancera2024,
  author = {Garzon-Mancera, Nicolas D and Khasiyev, Farid and Del Brutto, Victor J and Spagnolo Allende, Antonio J and Wright, Clinton B and Elkind, Mitchell and Rundek, Tatjana and Del Brutto, Oscar H and Gutierrez, Jose},
  title = {Validation of bedside manual versus automated measurements of brain arterial diameters from MR angiography},
  journal = {Journal of Neuroimaging},
  year = {2024},
  doi = {10.1111/jon.13217}
}
Kostenlos starten →