EUVIMEDEUVIMED entdecken
Crossref

Influence of Experimental Lighting Conditions on Digital Shade Matching and Intraoral Scanning Accuracy: A Clinical Study

Yong-Qing Guo, Kai-Jin Lin, Marzia Jannat Marfi, Lin Ni, Hong-Lei Lin, Hao Yu iD

Journal of Esthetic and Restorative Dentistry · 25.06.2026

DOI: 10.1111/jerd.70222 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Esthetic and Restorative Dentistry, online erschienen am 25.06.2026. Verfasst von Yong-Qing Guo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College…. Die Arbeit nennt 55 Literaturangaben. Gefördert von: Fujian Provincial Department of Science and Technology, Fujian Provincial University-Industry-Research Collaborative Innovation Project, Fujian Provincial Key Clinical Specialty Development Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the in vivo effect of varying experimental lighting conditions on the digital shade determination and scanning accuracy (trueness and precision) of two intraoral scanners (IOSs). Material and Methods The maxillary arches of 10 volunteers were scanned using two IOSs (Trios 4 wireless, 3Shape A/S [TR]; and Primescan, Dentsply Sirona [PR]). Scans were performed under four illuminance levels (0, 500, 1000, and 2500 lx) with scanner‐specific color temperature (TR: 5500 K; PR: 4100 K). Digital shade selection was performed at the middle third of the right central incisor against visual consensus by three experts for Vita toothguide Classical (VC) and Vita toothguide 3D‐Master (VM) shade guides. Scanning accuracy was assessed by superimposing IOS scans onto reference datasets obtained by digitizing conventional stone models with a laboratory scanner (InEos X5; Dentsply Sirona). Shade matching capability (accuracy and reliability) was also evaluated. Data were statistically analyzed using one‐way ANOVA ( α = 0.05).

Results

Ambient lighting significantly influenced digital shade matching and scanning trueness ( p < 0.05). For shade matching accuracy, TR demonstrated the highest values at 1000 lx/5500 K (VC: 93.33% ± 14.05%; VM: 76.67% ± 22.50%), while PR performed best at 2500 lx/4100 K (VC: 96.67% ± 10.54%; VM: 50.00% ± 28.33%). TR produced significantly lower reliability results at the “no‐light” (0 lx) condition ( p < 0.05), whereas PR displayed no significant difference among groups ( p > 0.05). For scanning trueness, TR exhibited the lowest deviation at 1000 lx/5500 K (104.04 ± 20.88 μm), while PR performed best at 2500 lx/4100 K (100.78 ± 19.36 μm).

Conclusions

Ambient lighting conditions significantly affected IOS performance in vivo. The optimal conditions were scanner‐dependent: TR performed best under typical examination room lighting (1000 lx, 5500 K), while PR excelled under dental operatory lighting (2500 lx, 4100 K). Clinical Significance To optimize digital impressions and esthetic shade matching, clinicians should adjust ambient lighting according to the specific requirements of the intraoral scanner being used.

Schlagwörter

Stichwörter der Autor:innen

accuracyambient light scanning conditionsdigital impressionsilluminationintraoral scannertrueness

Autor:innen und Institutionen

  • Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical Un…
  • Overseas Education College, Fujian Medical University, Fuzhou, Fujian, China.
  • Department of Applied Prosthodontics, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan.

ORCID-Profile: Hao Yu

Förderung

  • Fujian Provincial Department of Science and Technology
  • Fujian Provincial University-Industry-Research Collaborative Innovation Project
  • Fujian Provincial Key Clinical Specialty Development Program

Zitieren

APA

Guo, Y. Q., Lin, K. J., Marfi, M. J., Ni, L., Lin, H. L., & Yu, H. (2026). Influence of Experimental Lighting Conditions on Digital Shade Matching and Intraoral Scanning Accuracy: A Clinical Study. Journal of Esthetic and Restorative Dentistry. https://doi.org/10.1111/jerd.70222

Vancouver

Guo YQ, Lin KJ, Marfi MJ, Ni L, Lin HL, Yu H. Influence of Experimental Lighting Conditions on Digital Shade Matching and Intraoral Scanning Accuracy: A Clinical Study. Journal of Esthetic and Restorative Dentistry. 2026. doi:10.1111/jerd.70222

BibTeX
@article{Guo2026,
  author = {Guo, Yong-Qing and Lin, Kai-Jin and Marfi, Marzia Jannat and Ni, Lin and Lin, Hong-Lei and Yu, Hao},
  title = {Influence of Experimental Lighting Conditions on Digital Shade Matching and Intraoral Scanning Accuracy: A Clinical Study},
  journal = {Journal of Esthetic and Restorative Dentistry},
  year = {2026},
  doi = {10.1111/jerd.70222}
}
Kostenlos starten →